The DOI matches its Crossref record.
Complete roughness and conductivity corrections for Casimir force measurement
Open accessAbstract
We consider detailed roughness and conductivity corrections to the Casimir force in the recent Casimir force measurement employing an atomic force microscope. The roughness of the test bodies---a metal plate and a sphere---was investigated with the atomic force microscope and the scanning electron microscope, respectively. It consists of separate crystals of different heights and a stochastic background. The amplitude of roughness relative to the zero roughness level was determined and the corrections to the Casimir force were calculated up to the fourth order in a small parameter (which is this amplitude divided by the distance between the two test bodies). Also the corrections due to finite conductivity were found up to fourth order in relative penetration depths of electromagnetic zero-point oscillations into the metal. The theoretical result for the configuration of a sphere above a plate taking into account both corrections is in excellent agreement with the measured Casimir force.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in the Casimir Effect
Bordag, M., Klimchitskaya, G. L., Mohideen, U., & Mostepanenko, V. M. (2009) · doi:10.1093/acprof:oso/9780199238743.001.0001 · Cited by 1,284
Self-citationThe Casimir force between real materials: Experiment and theory
Klimchitskaya, G. L., Mohideen, U., & Mostepanenko, V. M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1827 · Cited by 834
Self-citationT ESTS OF THE G RAVITATIONAL I NVERSE-S QUARE L AW
Adelberger, E. G., Heckel, B. R., & Nelson, A. E. (2003) · Annual Review of Nuclear and Particle Science · doi:10.1146/annurev.nucl.53.041002.110503 · Cited by 819
Decca, R. S., López, D., Fischbach, E., Klimchitskaya, G. L., Krause, D. E., & Mostepanenko, V. M. (2007) · Physical Review D · doi:10.1103/physrevd.75.077101 · Cited by 414
Self-citationThermal Effects on the Casimir Force in the 0.1–5μmRange
Boström, M., & Sernelius, B. E. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.4757 · Cited by 329
Metadata
- Authors
- Klimchitskaya, G. L., Roy, A., Mohideen, U., & Mostepanenko, V. M.
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 1999-11-01
- Volume
- 60
- Issue
- 5
- Pages
- 3487-3495
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2037586776
- Cited by
- 167
- References
- 0
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complete roughness and conductivity corrections for Casimir force measurement. https://app.cochat.ai/papers/10.1103/physreva.60.3487
- The paper
- Klimchitskaya, G. L., Roy, A., Mohideen, U., & Mostepanenko, V. M. (1999). Complete roughness and conductivity corrections for Casimir force measurement. Physical Review A. https://doi.org/10.1103/physreva.60.3487
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.