Stability enhancement by joint phase measurements in a single cold atomic fountain
Open accessAbstract
We propose a method of joint interrogation in a single atom interferometer which overcomes the dead time between consecutive measurements in standard cold atomic fountains. The joint operation enables for a faster averaging of the Dick effect associated with the local oscillator noise in clocks and with vibration noise in cold atom inertial sensors. Such an operation allows one to achieve the lowest stability limit due to atom shot noise. We demonstrate a multiple joint operation in which up to five clouds of atoms are interrogated simultaneously in a single setup. The essential feature of multiple joint operation, demonstrated here for a microwave Ramsey interrogation, can be generalized to go beyond the current stability limit associated with dead times in present-day cold atom interferometer inertial sensors.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The effect of aliased noise in the two systems has the same magnitude but opposite sign.
“the effect of the aliased noise in the two systems has the same magnitude but opposite sign 37 .”
From Ultrastable optical clock with two cold-atom ensembles (2017) · cites this paper as [37]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 22 · Cited by 40
Research works printed but not linked: 9
- [5]R. Geiger, V. M´ enoret, G. Stern, N. Zahzam, P. Cheinet, B. Battelier, A. Villing, F. Moron, M. Lours, Y. Bidel, A. Bresson, A. Landragin and P. Bouyer, Nat. Communications 2, 474 (2011).
- [6]B. Barrett, P.-A. Gominet, E. Cantin, L. AntoniMicollier, A. Bertoldi, B. Battelier, P. Bouyer, J. Lautier, A. Landragin, to be published in Proceedings of the International School of Physics 'Enrico Fermi' on Atom Interferometry, arXiv:1311.7033 (2013). · arXiv
- [11]S. Bize., Y. Sortais, P. Lemonde, S. Zhang, P. Laurent, G. Santarelli, C. Salomon, and A. Clairon, IEEE Trans Ultrason Ferroelectr Freq Control. 47 , 1253 (2000).
- [14]L. Devenoges, A. Stefanov, A. Joyet, P. Thomann, and G. Di Domenico, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control 59 , 211 (2012).
- [18]F. Fuezesi, A. Jornod, P. Thomann, M. D. Plimmer, G. Dudle, R. Moser, L. Sache, and H. Bleuler, Review of Scientific Instruments 78 , 103109 (2007).
- [19]P. Lemonde, G. Santarelli, P. Laurent, F. Pereira dos Santos, A. Clairon, and C. Salomon, in Proc. of the 1998 IEEE Int. Freq. Control Symp. (1998), pp. 110-115, ISSN 1075-6787.
- [20]P. Cheinet, B. Canuel, F. Pereira Dos Santos, A. Gauguet, F. Leduc, and A. Landragin, IEEE Trans. on Instrum. Meas 57 , 1141 (2008).
- [21]S. Grop, P. Bourgeois, R. Boudot, Y. Kersal´ e, E. Rubiola, and V. Giordano, Electronic Letters 46, 420 (2010).
- [22]J. G. Hartnett, N. R. Nand, and C. Lu, Applied Physics Letters 100 , 183501 (2012).
- Authors
- Meunier, M., Dutta, I., Geiger, R., Guerlin, C., Garrido Alzar, C. L., & Landragin, A.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Venue
- Physical Review A
- Publisher
- American Physical Society (APS)
- Published
- 2014-12-22
- Volume
- 90
- Issue
- 6
- ISSN
- 0556-2791 (ISSN-L)
- 1050-2947
- 1094-1622
- OpenAlex
- W2043270286
- Cited by
- 40
- References
- 22
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2022: 4 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 5 · 2017: 4 · 2016: 13 · 2015: 2 · 2014: 2
- FWCI
- 3.48
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- Physical Review A (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- HAL (submittedVersion)
- arXiv (Cornell University)
- Funders
- Division of Grants and Agreements
- Centre National d’Etudes Spatiales
- Labex
- Agence Nationale de la Recherche (ANR-10-LABX-48-01)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- atom interferometry, dead time, Dick effect, local oscillator noise, vibration noise, shot noise, inertial sensors, clock stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review