Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Fidelity and trace-norm distances for quantifying coherence

Open access
Shao, Lian-He, Xi, Zhengjun, Fan, Heng, Li, Yongming·2015·Physical Review A

Abstract

We investigate the coherence measures induced by fidelity and trace norm, based on the coherence quantification recently proposed by Baumgratz et al. [T. Baumgratz, M. Cramer, and M. B. Plenio, Phys. Rev. Lett. 113, 140401 (2014)]. We show that the fidelity of coherence does not in general satisfy the monotonicity requirement as a measure of coherence under the subselection of the measurement condition. We find that the trace norm of coherence can act as a measure of coherence for qubits and some special class of qutrits with some restrictions on the incoherent operators, while the general case needs to be explored further.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physreva.91.042120

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 273

Metadata

Authors
Shao, L.-H., Xi, Z., Fan, H., & Li, Y.
Venue
Physical Review A
Published
2015-04-15
Volume
91
Issue
4
ISSN
  • 0556-2791 (ISSN-L)
  • 1050-2947
  • 1094-1622
OpenAlex
W2079980148
Cited by
273
References
14
FWCI
32.85
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fidelity and trace-norm distances for quantifying coherence. https://app.cochat.ai/papers/10.1103/physreva.91.042120
The paper
Shao, L.-H., Xi, Z., Fan, H., & Li, Y. (2015). Fidelity and trace-norm distances for quantifying coherence. Physical Review A. https://doi.org/10.1103/physreva.91.042120

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.