Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 210

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Low-frequency inelastic light scattering from chalcogenide glasses and alloys

Nemanich, R. J.·1977·Physical Review B

Abstract

Polarized low-frequency Raman and Brillouin spectra of the chalcogenide glasses ${\mathrm{As}}_{2}$${\mathrm{S}}_{3}$, Ge${\mathrm{S}}_{2}$, Ge${\mathrm{Se}}_{2}$, and ${\mathrm{As}}_{2}$${\mathrm{Se}}_{3}$ and the glass alloy system ${({\mathrm{As}}_{2}{\mathrm{S}}_{3})}_{1\ensuremath{-}x}{(\mathrm{Ge}{\mathrm{S}}_{2})}_{x}$ have been measured using the near infrared 7525 or 7993 \AA{} lines of a krypton laser. The low-temperature $T\ensuremath{\sim}10$ K spectra of the four binary glasses indicate that the Raman coupling constant exhibits an ${\ensuremath{\omega}}^{2}$ frequency dependence in the limit $\ensuremath{\omega}\ensuremath{\rightarrow}0$. In addition it is demonstrated that the spectral distribution of the low-frequency low-temperature Raman coupling constant can be described by a model proposed by Martin and Brenig. By fitting the predicted spectra of the model to the experimentally obtained spectra, the structural correlation ranges of the glasses have been determined. It is found that the structural correlation ranges of the ${\mathrm{As}}_{2}$${\mathrm{S}}_{3}$ and ${\mathrm{As}}_{2}$${\mathrm{Se}}_{3}$ glasses are 6.5 \ifmmode\pm\else\textpm\fi{} 1 \AA{}, while those of the Ge${\mathrm{S}}_{2}$ and Ge${\mathrm{Se}}_{2}$ glasses are 8.5 \ifmmode\pm\else\textpm\fi{} 1 \AA{}. These results are compared with values of structural correlations obtained from x-ray diffraction spectra and optic-mode Raman spectra. The depolarization spectra predicted from the Martin and Brenig model are found to deviate significantly from the observed low-frequency depolarization spectra of the chalcogenide glasses. At higher temperatures the low-frequency Raman spectra of all samples exhibit a feature apparently centered at 0 frequency shift which cannot be described by the model of Martin and Brenig. A similar feature termed the light scattering excess has been reported for the low-frequency Raman spectrum of fused silica. A recent model by Theodorakopoulos and J\"ackle describes the light scattering excess in terms of two-level defect states. The temperature dependence, depolarization ratio, and spectral distribution of the light-scattering excess are interpreted using this model and recent ultrasonic attenuation measurements. The composition dependence of both the structural correlation range and the light-scattering excess is presented for the alloy system of ${({\mathrm{As}}_{2}{\mathrm{S}}_{3})}_{1\ensuremath{-}x}{(\mathrm{Ge}{\mathrm{S}}_{2})}_{x}$.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevb.16.1655

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 210

Metadata

Authors
Nemanich, R. J.
Venue
Physical Review B
Published
1977-08-15
Volume
16
Issue
4
Pages
1655-1674
ISSN
0556-2805 (ISSN-L)
OpenAlex
W2068828835
Cited by
210
References
1
FWCI
6.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.