The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Photoabsorption spectra of sodium clusters
Abstract
Absolute photoabsorption cross sections of free neutral sodium clusters containing from N=3 to 40 atoms are presented. Investigation of a wide continuous range of cluster sizes reveals the size development of the photoabsorption behavior. In the smallest clusters the absorption is moleculelike. A transition to collective electronic excitations (surface plasmons) occurs in the size range of N=3 to 5. For clusters with N=6 to 12 atoms the surface plasma resonances are particularly well defined, and their positions are consistent with the predictions of an ellipsoidal shell model. The cluster shapes can be deduced from the observed resonance positions; the data provide a sensitive measurement of the relative axis lengths of ellipsoidal clusters. For clusters containing N\ensuremath{\gtrsim}3 atoms, the plasma resonances do not always coincide with the positions predicted by the ellipsoidal shell model. In addition to these resonances, which dominate the spectra, there are three distinct wavelength regions within which absorption occurs for all investigated clusters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen
Mie, G. (1908) · Annalen der Physik · doi:10.1002/andp.19083300302 · Cited by 11,537
Cited by
Theoretical Studies of Plasmonics using Electronic Structure Methods
Morton, S. M., Silverstein, D. W., & Jensen, L. (2011) · Chemical Reviews · doi:10.1021/cr100265f · Cited by 474
Metadata
- Authors
- Selby, K., Kresin, V., Masui, J., Vollmer, M., de Heer, W. A., Scheidemann, A., & Knight, W. D.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1991-02-15
- Volume
- 43
- Issue
- 6
- Pages
- 4565-4572
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2054721489
- Cited by
- 215
- References
- 1
- FWCI
- 31.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.