The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Full correction of the self-absorption in soft-fluorescence extended x-ray-absorption fine structure
Abstract
The amplitude of the extended x-ray-absorption fine structure of concentrated samples measured in the fluorescence mode (FLEXAFS) as well as the overall shape of the fluorescence-yield spectra strongly depend on the detection geometry through the self-absorption effect. In these cases, a conventional EXAFS analysis can lead to systematic errors in the determination of physical parameters. We studied the distortions in the FLEXAFS spectra through the self-absorption effect measuring the FLEXAFS of a NiO single crystal above the oxygen K edge for various detection geometries. We show that knowing the stoichiometry of the sample we can fully correct for the self-absorption effect using a simple theory and obtain the correct, geometry-independent oxygen EXAFS of NiO. The correction procedure presented here for the prototype system of NiO is generally applicable and should be the first step in the analysis of FLEXAFS data of concentrated samples. We calculate the information depth of the fluorescence detection as a function of the experimental geometry. The knowledge of the self-absorption in relationship to the information depth allows the determination of the optimum experimental setup.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic subshell photoionization cross sections and asymmetry parameters: 1 ⩽ Z ⩽ 103
Yeh, J. J., & Lindau, I. (1985) · Atomic Data and Nuclear Data Tables · doi:10.1016/0092-640x(85)90016-6 · Cited by 4,978
Cited by
Oxidation state and coordination of Fe in minerals: An Fe K-XANES spectroscopic study
Wilke, M., Farges, F., Petit, P.-E., Brown, G. E., & Martin, F. (2001) · American Mineralogist · doi:10.2138/am-2001-5-612 · Cited by 1,118
Oxygen K-edge X-ray Absorption Spectra
Frati, F., Hunault, M. O. J. Y., & de Groot, F. M. F. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00439 · Cited by 768
Quantitative Speciation of Heavy Metals in Soils and Sediments by Synchrotron X-ray Techniques
Manceau, A., Marcus, M. A., & Tamura, N. (2002) · Reviews in Mineralogy and Geochemistry · doi:10.2138/gsrmg.49.1.341 · Cited by 451
Analysis of Soils and Minerals Using X‐ray Absorption Spectroscopy
Kelly, S. D., Hesterberg, D., & Ravel, B. (2008) · SSSA Book Series · doi:10.2136/sssabookser5.5.c14 · Cited by 400
Bargar, J. R., Brown, G. E., & Parks, G. A. (1997) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(97)00124-5 · Cited by 257
Gräfe, M., Donner, E., Collins, R. N., & Lombi, E. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.02.044 · Cited by 186
Isaure, M.-P., Laboudigue, A., Manceau, A., Sarret, G., Tiffreau, C., Trocellier, P., Lamble, G., Hazemann, J.-L., & Chateigner, D. (2002) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(01)00875-4 · Cited by 165
Metadata
- Authors
- Tröger, L., Arvanitis, D., Baberschke, K., Michaelis, H., Grimm, U., & Zschech, E.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1992-08-01
- Volume
- 46
- Issue
- 6
- Pages
- 3283-3289
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2074410446
- Cited by
- 476
- References
- 1
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.