The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Optical Constants of the Noble Metals
Abstract
The optical constants $n$ and $k$ were obtained for the noble metals (copper, silver, and gold) from reflection and transmission measurements on vacuum-evaporated thin films at room temperature, in the spectral range 0.5-6.5 eV. The film-thickness range was 185-500 \AA{}. Three optical measurements were inverted to obtain the film thickness $d$ as well as $n$ and $k$. The estimated error in $d$ was \ifmmode\pm\else\textpm\fi{} 2 \AA{}, and that in $n$, $k$ was less than 0.02 over most of the spectral range. The results in the film-thickness range 250-500 \AA{} were independent of thickness, and were unchanged after vacuum annealing or aging in air. The free-electron optical effective masses and relaxation times derived from the results in the near infrared agree satisfactorily with previous values. The interband contribution to the imaginary part of the dielectric constant was obtained by subtracting the free-electron contribution. Some recent theoretical calculations are compared with the results for copper and gold. In addition, some other recent experiments are critically compared with our results.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For circularly polarized light, on the other hand, the phase gradient is geometrically induced by spatially varying the orientation of the identical nanobricks, hereby leading to a so-called Pancharatnam-Berry phase[34, 35].”
From Plasmonic metagratings for simultaneous determination of Stokes parameters (2015) · cites this paper as [34]
Citations
Cites
Optical Properties of Ag and Cu
Ehrenreich, H., & Philipp, H. R. (1962) · Physical Review · doi:10.1103/physrev.128.1622 · Cited by 1,284
American Institute of Physics Handbook
(1957) · Journal of the Optical Society of America · doi:10.1364/josa.47.000330 · Cited by 1,067
Relativistic Band Calculation and the Optical Properties of Gold
Christensen, N. E., & Seraphin, B. O. (1971) · Physical review. B, Solid state · doi:10.1103/physrevb.4.3321 · Cited by 491
Investigation of the Optical Properties of Au by Means of Thin Semitransparent Films
Thèye, M. L. (1970) · Physical review. B, Solid state · doi:10.1103/physrevb.2.3060 · Cited by 371
Optical Properties of Noble Metals. II.
Cooper, B. R., Ehrenreich, H., & Philipp, H. R. (1965) · Physical Review · doi:10.1103/physrev.138.a494 · Cited by 294
Basic problems in thin film physics
(1968) · Vacuum · doi:10.1016/0042-207x(68)92816-9 · Cited by 232
Roberts, S. (1960) · Physical Review · doi:10.1103/physrev.118.1509 · Cited by 213
Determination of Optical Constants from Intensity Measurements at Normal Incidence
Nilsson, P. O. (1968) · Applied Optics · doi:10.1364/ao.7.000435 · Cited by 211
Infrared Reflectance of Aluminum Evaporated in Ultra-High Vacuum
Bennett, H. E., Silver, M., & Ashley, E. J. (1963) · Journal of the Optical Society of America · doi:10.1364/josa.53.001089 · Cited by 203
Precision Measurement of Absolute Specular Reflectance with Minimized Systematic Errors
Bennett, H. E., & Koehler, W. F. (1960) · Journal of the Optical Society of America · doi:10.1364/josa.50.000001 · Cited by 200
Research works printed but not linked: 5
- P. O. Nilsson, 1970, Physik Kondensierten Materie, 11, 1
- F. Stern, 1963, Solid State Physics
- D. L. Decker, 1971, J. Opt. Soc. Am., 61, 679A
- L. Ward, 1969, Brit. J. Appl. Phys., 2, 301
- D. Malé, 1950, Compt. Rend., 230, 1349
Cited by
Sorted by citations
Plasmonics: Fundamentals and Applications
Maier, S. A. (2007) · Springer eBooks · doi:10.1007/0-387-37825-1 · Cited by 9,943
Moskovits, M. (1985) · Reviews of Modern Physics · doi:10.1103/revmodphys.57.783 · Cited by 5,475
Jain, P. K., Lee, K.-S., El‐Sayed, I. H., & El‐Sayed, M. A. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp057170o · Cited by 4,609
Localized Surface Plasmon Resonance Sensors
Mayer, K. M., & Hafner, J. H. (2011) · Chemical Reviews · doi:10.1021/cr100313v · Cited by 4,376
Optical properties of metallic films for vertical-cavity optoelectronic devices
Rakić, A. D., Djurišić, A. B., Elazar, J. M., & Majewski, M. L. (1998) · Applied Optics · doi:10.1364/ao.37.005271 · Cited by 4,351
Metadata
- Authors
- Johnson, P. B., & Christy, R. W.
- Affiliations
- Dartmouth College (US)
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1972-12-15
- Volume
- 6
- Issue
- 12
- Pages
- 4370-4379
- ISSN
- 0556-2805 (ISSN-L)
- OpenAlex
- W2083926174
- Cited by
- 20,094
- References
- 36
- Citations by year
- 2026: 704 · 2025: 761 · 2024: 864 · 2023: 887 · 2022: 1059 · 2021: 1051 · 2020: 1100 · 2019: 1140 · 2018: 1158 · 2017: 1144 · 2016: 1185 · 2015: 1108 · 2014: 1116 · 2013: 1056 · 2012: 988
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physical review. B, Solid state (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Condensed Matter Physics › Surface and Thin Film Phenomena
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Plasmonic and Surface Plasmon Research
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Optical Coatings and Gratings
- Keywords
- optical constants, refractive index, extinction coefficient, noble metals, copper, silver, gold, thin films, film thickness measurement, relaxation time, dielectric constant, near-infrared, vacuum annealing, air aging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review