Optical third-harmonic generation of fused silica in gas atmosphere: Absolute value of the third-order nonlinear optical susceptibilityχ(3)
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
We report on a calibration procedure based on third-harmonic generation, which yields absolute values for ${\ensuremath{\chi}}^{(3)}.$ By calibrating the nonlinear susceptibility ${\ensuremath{\chi}}^{(3)}$ of fused silica against the established, quantum chemically calculated second-order hyperpolarizabilities \ensuremath{\gamma} of various gases at different pressures, we determine reliable absolute values for fused silica. We propose a standard third-order nonlinear optical susceptibilities ${\ensuremath{\chi}}^{(3)}$ of fused silica ${\ensuremath{\chi}}^{(3)}(\ensuremath{-}3\ensuremath{\omega},\ensuremath{\omega},\ensuremath{\omega},\ensuremath{\omega})=(2.0\ifmmode\pm\else\textpm\fi{}0.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}22}{\mathrm{m}}^{2}{/\mathrm{V}}^{2}$ at the wavelength 1.064 \ensuremath{\mu}m and ${\ensuremath{\chi}}^{(3)}(\ensuremath{-}3\ensuremath{\omega},\ensuremath{\omega},\ensuremath{\omega},\ensuremath{\omega})=(1.6\ifmmode\pm\else\textpm\fi{}0.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}22}{\mathrm{m}}^{2}{/\mathrm{V}}^{2}$ at 1.907 \ensuremath{\mu}m. These results are in excellent agreement with the cascading experiments reported by Bosshard et al. [Phys. Rev. B 61, 10 688 (2000)].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sensitive measurement of optical nonlinearities using a single beam
Sheik-Bahae, M., Said, A. A., Wei, T.-H., Hagan, D. J., & Van Stryland, E. W. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.53394 · Cited by 9,053
Handbook of Chemistry and Physics.
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-934_3 · Cited by 2,559
Third-order optical susceptibilities of liquids and solids
Hellwarth, R. W. (1977) · Progress in Quantum Electronics · doi:10.1016/0079-6727(79)90002-8 · Cited by 669
Effects of focusing on third-order nonlinear processes in isotropic media
Bjorklund, G. (1975) · IEEE Journal of Quantum Electronics · doi:10.1109/jqe.1975.1068619 · Cited by 491
Optical Third Harmonic Generation in Gases by a Focused Laser Beam
Ward, J. F., & New, G. H. C. (1969) · Physical Review · doi:10.1103/physrev.185.57 · Cited by 462
Milam, D. (1998) · Applied Optics · doi:10.1364/ao.37.000546 · Cited by 411
Lehmeier, H. J., Leupacher, W., & Penzkofer, A. (1985) · Optics Communications · doi:10.1016/0030-4018(85)90069-0 · Cited by 216
Bosshard, C., Gubler, U., Kaatz, P., Mazerant, W., & Meier, U. (2000) · Physical review. B, Condensed matter · doi:10.1103/physrevb.61.10688 · Cited by 122
Self-citationCascading in optical third-harmonic generation by crystalline quartz
Meredith, G. R. (1981) · Physical review. B, Condensed matter · doi:10.1103/physrevb.24.5522 · Cited by 95
Metadata
- Authors
- Gubler, U., & Bosshard, C.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2000-04-15
- Volume
- 61
- Issue
- 16
- Pages
- 10702-10710
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W2080145307
- Cited by
- 168
- References
- 9
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.