The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Coherence of single spins coupled to a nuclear spin bath of varying density
Open accessAbstract
The dynamics of single electron and nuclear spins in a diamond lattice with different $^{13}\text{C}$ nuclear spin concentration is investigated. It is shown that coherent control of up to three individual nuclei in a dense nuclear spin cluster is feasible. The free-induction decays of nuclear spin Bell states and single nuclear coherences among $^{13}\text{C}$ nuclear spins are compared and analyzed. Reduction in a free-induction-decay time ${T}_{2}^{\ensuremath{\ast}}$ and a coherence time ${T}_{2}$ upon increase in nuclear spin concentration has been found. For pure diamond, ${T}_{2}^{\ensuremath{\ast}}$ as long as $30\text{ }\ensuremath{\mu}\text{s}$ and ${T}_{2}$ of up to 0.65 ms for the electron spin has been observed. The $^{13}\text{C}$ concentration dependence of ${T}_{2}^{\ensuremath{\ast}}$ is explained by Fermi contact and dipolar interactions with nuclei in the lattice. It has been found that ${T}_{2}$ decreases approximately as $1/n$, where $n$ is $^{13}\text{C}$ concentration, which corresponds to the reported theoretical line of ${T}_{2}$ for an electron spin interacting with a nuclear spin bath.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum register based on individual electronic and nuclear spin qubits in diamond
Dutt, M. V. G., Childress, L., Jiang, L., Togan, E., Maze, J., Jelezko, F., Zibrov, A. S., Hemmer, P. R., & Lukin, M. D. (2007) · Science · doi:10.1126/science.1139831 · Cited by 1,287
Self-citation
Cited by
The nitrogen-vacancy colour centre in diamond
Doherty, M. W., Manson, N. B., Delaney, P., Jelezko, F., Wrachtrup, J., & Hollenberg, L. C. L. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.02.001 · Cited by 2,866
Self-citationSensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247
High-Precision Nanoscale Temperature Sensing Using Single Defects in Diamond
Neumann, P., Jakobi, I., Dolde, F., Burk, C., Reuter, R., Waldherr, G., Honert, J., Wolf, T., Brunner, A., Shim, J. H., et al. (2013) · Nano Letters · doi:10.1021/nl401216y · Cited by 785
Self-citationCoherent coupling of a superconducting flux qubit to an electron spin ensemble in diamond
Zhu, X., Saito, S., Kemp, A., Kakuyanagi, K., Karimoto, S.-I., Nakano, H., Munro, W. J., Tokura, Y., Everitt, M. S., Nemoto, K., et al. (2011) · Nature · doi:10.1038/nature10462 · Cited by 450
Self-citationJarmola, A., Acosta, V. M., Jensen, K., Chemerisov, S., & Budker, D. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.197601 · Cited by 417
Metadata
- Authors
- Mizuochi, N., Neumann, P., Rempp, F., Beck, J., Jacques, V., Siyushev, P., Nakamura, K., Twitchen, D. J., Watanabe, H., Yamasaki, S., Jelezko, F., & Wrachtrup, J.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2009-07-13
- Volume
- 80
- Issue
- 4
- Pages
- 041201
- ISSN
- 1098-0121 (ISSN-L)
- 1550-235X
- OpenAlex
- W2072726797
- Cited by
- 225
- References
- 1
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.