Ultrasensitive diamond magnetometry using optimal dynamic decoupling
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Magnetometry techniques based on nitrogen-vacancy (NV) defects in diamond have received much attention of late as a means to probe nanoscale magnetic environments. The sensitivity of a single NV magnetometer is primarily determined by the transverse spin-relaxation time, ${T}_{2}$. Current approaches to improving the sensitivity employ crystals with a high NV density at the cost of spatial resolution or extend ${T}_{2}$ via the manufacture of novel isotopically pure diamond crystals. We adopt a complementary approach in which optimal dynamic decoupling techniques extend coherence times out to the self-correlation time of the spin bath. This suggests single spin, room-temperature magnetometer sensitivities as low as $5\text{ }\text{pT}\text{ }{\text{Hz}}^{\ensuremath{-}1/2}$ may be possible with current technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Keeping a Quantum Bit Alive by Optimized π -Pulse Sequences
Uhrig, G. S. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.100504 · Cited by 716
Cited by
The nitrogen-vacancy colour centre in diamond
Doherty, M. W., Manson, N. B., Delaney, P., Jelezko, F., Wrachtrup, J., & Hollenberg, L. C. L. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.02.001 · Cited by 2,866
Self-citationElectric-field sensing using single diamond spins
Dolde, F., Fedder, H., Doherty, M. W., Nöbauer, T., Rempp, F., Balasubramanian, G., Wolf, T., Reinhard, F., Hollenberg, L. C. L., Jelezko, F., et al. (2011) · Nature Physics · doi:10.1038/nphys1969 · Cited by 1,334
Self-citationQuantum measurement and orientation tracking of fluorescent nanodiamonds inside living cells
McGuinness, L. P., Yan, Y., Stacey, A., Simpson, D. A., Hall, L. T., Maclaurin, D., Prawer, S., Mulvaney, P., Wrachtrup, J., Caruso, F., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.64 · Cited by 666
Self-citationTheory of the ground-state spin of the NV−center in diamond
Doherty, M. W., Dolde, F., Fedder, H., Jelezko, F., Wrachtrup, J., Manson, N. B., & Hollenberg, L. C. L. (2012) · Physical Review B · doi:10.1103/physrevb.85.205203 · Cited by 389
Self-citationRobust Decoupling Techniques to Extend Quantum Coherence in Diamond
Ryan, C. A., Hodges, J. S., & Cory, D. G. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.200402 · Cited by 375
Metadata
- Authors
- Hall, L. T., Hill, C. D., Cole, J. H., & Hollenberg, L. C. L.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 2010-07-29
- Volume
- 82
- Issue
- 4
- ISSN
- 1098-0121 (ISSN-L)
- 1550-235X
- OpenAlex
- W2093546232
- Cited by
- 74
- References
- 1
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.