Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 509

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

First results from the CRESST-III low-mass dark matter program

Open access
Abdelhameed, A. H., Angloher, G., Bauer, P., Bento, A., Bertoldo, E., Bucci, C., Canonica, L., D’Addabbo, A., Defay, X., Di Lorenzo, S., Erb, A., Feilitzsch, F. v., Fichtinger, S., Ferreiro Iachellini, N., Fuss, A., Gorla, P., Hauff, D., Jochum, J., Kinast, A., Kluck, H., Kraus, H., Langenkämper, A., Mancuso, M., Mokina, V., Mondragon, E., Münster, A., Olmi, M., Ortmann, T., Pagliarone, C., Pattavina, L., Petricca, F., Potzel, W., Pröbst, F., Reindl, F., Rothe, J., Schäffner, K., Schieck, J., Schipperges, V., Schmiedmayer, D., Schönert, S., Schwertner, C., Stahlberg, M., Stodolsky, L., Strandhagen, C., Strauss, R., Türkoǧlu, C., Usherov, I., Willers, M., Zema, V., CRESST Collaboration·2019·Physical Review D

Abstract

The CRESST experiment is a direct dark matter search which aims to measure interactions of potential dark matter particles in an Earth-bound detector. With the current stage, CRESST-III, we focus on a low energy threshold for increased sensitivity towards light dark matter particles. In this paper we describe the analysis of one detector operated in the first run of CRESST-III (05/2016--02/2018) achieving a nuclear recoil threshold of 30.1 eV. This result was obtained with a 23.6 g ${\mathrm{CaWO}}_{4}$ crystal operated as a cryogenic scintillating calorimeter in the CRESST setup at the Laboratori Nazionali del Gran Sasso (LNGS). Both the primary phonon (heat) signal and the simultaneously emitted scintillation light, which is absorbed in a separate silicon-on-sapphire light absorber, are measured with highly sensitive transition edge sensors operated at $\ensuremath{\sim}15\text{ }\text{ }\mathrm{mK}$. The unique combination of these sensors with the light element oxygen present in our target yields sensitivity to dark matter particle masses as low as $160\text{ }\text{ }\mathrm{MeV}/{\mathrm{c}}^{2}$.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevd.100.102002

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

Metadata

Authors
Abdelhameed, A. H., Angloher, G., Bauer, P., Bento, A., Bertoldo, E., Bucci, C., Canonica, L., D’Addabbo, A., Defay, X., Di Lorenzo, S., Erb, A., Feilitzsch, F. V., Fichtinger, S., Ferreiro Iachellini, N., Fuss, A., Gorla, P., Hauff, D., Jochum, J., Kinast, A., Kluck, H., Kraus, H., Langenkämper, A., Mancuso, M., Mokina, V., Mondragon, E., Münster, A., Olmi, M., Ortmann, T., Pagliarone, C., Pattavina, L., Petricca, F., Potzel, W., Pröbst, F., Reindl, F., Rothe, J., Schäffner, K., Schieck, J., Schipperges, V., Schmiedmayer, D., Schönert, S., Schwertner, C., Stahlberg, M., Stodolsky, L., Strandhagen, C., Strauss, R., Türkoǧlu, C., Usherov, I., Willers, M., Zema, V., & CRESST Collaboration
Venue
Physical Review D
Published
2019-11-25
Volume
100
Issue
10
ISSN
  • 2470-0010 (ISSN-L)
  • 2470-0029
OpenAlex
W2989633088
Cited by
509
References
31
FWCI
33.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.