Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 399

The DOI matches its Crossref record.

CoGeNT: A search for low-mass dark matter usingp-type point contact germanium detectors

Open access
Aalseth, C. E., Barbeau, P. S., Colaresi, J., Collar, J. I., Diaz Leon, J., Fast, J. E., Fields, N. E., Hossbach, T. W., Knecht, A., Kos, M. S., Marino, M. G., Miley, H. S., Miller, M. L., Orrell, J. L., Yocum, K. M., CoGeNT Collaboration·2013·Physical Review D

Abstract

CoGeNT employs $p$-type point-contact (PPC) germanium detectors to search for weakly interacting massive particles (WIMPs). By virtue of its low-energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (${m}_{\ensuremath{\chi}}\ensuremath{\sim}10\text{ }\text{ }\mathrm{GeV}/{c}^{2}$). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instrumental stability, data analysis, and background estimation. A detailed background model is used to investigate the low-energy excess of events previously reported and to assess the possibility of temporal modulations in the low-energy event rate. Extensive simulations of all presently known backgrounds do not provide a viable background explanation for the excess of low-energy events in the CoGeNT data or the previously observed temporal variation in the event rate. Also reported for the first time is a determination of the surface (slow pulse rise time) event contamination in the data as a function of energy. We conclude that the CoGeNT detector technology is well suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevd.88.012002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 399

Metadata

Authors
Aalseth, C. E., Barbeau, P. S., Colaresi, J., Collar, J. I., Diaz Leon, J., Fast, J. E., Fields, N. E., Hossbach, T. W., Knecht, A., Kos, M. S., Marino, M. G., Miley, H. S., Miller, M. L., Orrell, J. L., Yocum, K. M., & CoGeNT Collaboration
Venue
Physical Review D
Published
2013-07-08
Volume
88
Issue
1
ISSN
  • 0556-2821 (ISSN-L)
  • 1550-7998
  • 1550-2368
OpenAlex
W2109115208
Cited by
399
References
0
FWCI
35.59
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CoGeNT: A search for low-mass dark matter usingp-type point contact germanium detectors. https://app.cochat.ai/papers/10.1103/physrevd.88.012002
The paper
Aalseth, C. E., Barbeau, P. S., Colaresi, J., Collar, J. I., Diaz Leon, J., Fast, J. E., Fields, N. E., Hossbach, T. W., Knecht, A., Kos, M. S., Marino, M. G., Miley, H. S., Miller, M. L., Orrell, J. L., Yocum, K. M., & CoGeNT Collaboration. (2013). CoGeNT: A search for low-mass dark matter usingp-type point contact germanium detectors. Physical Review D. https://doi.org/10.1103/physrevd.88.012002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.