The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Modified permutation-entropy analysis of heartbeat dynamics
Abstract
Heart rate variability (HRV) contains important information about the modulation of the cardiovascular system. Various methods of nonlinear dynamics (e.g., estimating Lyapunov exponents) and complexity measures (e.g., correlation dimension or entropies) have been applied to HRV analysis. Permutation entropy, which was proposed recently, has been widely used in many fields due to its conceptual and computational simplicity. It maps a time series onto a symbolic sequence of permutation ranks. The original permutation entropy assumes the time series under study has a continuous distribution, thus equal values are rare and can be ignored by ranking them according to their order of emergence, or broken by adding small random perturbations to ensure every symbol in a sequence is different. However, when the observed time series is digitized with lower resolution leading to a greater number of equal values, or the equalities represent certain characteristic sequential patterns of the system, it may not be rational to simply ignore or break them. In the present paper, a modified permutation entropy is proposed that, by mapping the equal value onto the same symbol (rank), allows for a more accurate characterization of system states. The application of the modified permutation entropy to the analysis of HRV is investigated using clinically collected data. Results show that modified permutation entropy can greatly improve the ability to distinguish the HRV signals under different physiological and pathological conditions. It can characterize the complexity of HRV more effectively than the original permutation entropy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
Cited by
Refined Composite Multiscale Dispersion Entropy and its Application to Biomedical Signals
(2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2679136 · Cited by 319
Metadata
- Authors
- Bian, C., Qin, C., Ma, Q. D. Y., & Shen, Q.
- Venue
- Physical Review E
- Publisher
- American Physical Society (APS)
- Published
- 2012-02-10
- Volume
- 85
- Issue
- 2
- Pages
- 021906-021906
- ISSN
- 1539-3755 (ISSN-L)
- 1550-2376
- OpenAlex
- W2318640187
- Cited by
- 198
- References
- 4
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modified permutation-entropy analysis of heartbeat dynamics. https://app.cochat.ai/papers/10.1103/physreve.85.021906
- The paper
- Bian, C., Qin, C., Ma, Q. D. Y., & Shen, Q. (2012). Modified permutation-entropy analysis of heartbeat dynamics. Physical Review E. https://doi.org/10.1103/physreve.85.021906
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.