Cited by 93Quantum optics and atomic interactionsNonlinear Photonic SystemsPhotorefractive and Nonlinear Optics

Effect of Nonlinearity on Adiabatic Evolution of Light

Open access
Lahini, Y., Pozzi, F., Sorel, M., Morandotti, R., Christodoulides, D. N., Silberberg, Y.·2008·Physical Review Letters

Abstract

We investigate the effect of nonlinearity in a system described by an adiabatically evolving Hamiltonian. Experiments are conducted in a three-core waveguide structure that is adiabatically varying with distance, in analogy to the stimulated Raman adiabatic passage process in atomic physics. In the linear regime, the system exhibits an adiabatic power transfer between two waveguides which are not directly coupled, with negligible power recorded in the intermediate coupling waveguide. In the presence of nonlinearity the adiabatic light passage is found to critically depend on the excitation power. We show how this effect is related to the destruction of the dark state formed in this configuration.

Integrity signals

Registry

Crossref · 10.1103/physrevlett.101.193901

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Frequency conversion of optical pulses in a nonlinear quadratic medium arising from group velocity mismatch provides a photonic analogue of ZB.

    “A second example of a photonic analogue of ZB is provided by the process frequency conversion of optical pulses in a nonlinear quadratic medium arising from group velocity mismatch [42].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lahini, Y., Pozzi, F., Sorel, M., Morandotti, R., Christodoulides, D. N., & Silberberg, Y.
Affiliations
  • Weizmann Institute of Science (IL)
  • University of Glasgow (GB)
  • Institut National de la Recherche Scientifique (CA)
  • University of Central Florida (US)
Venue
Physical Review Letters
Published
2008-11-05
Volume
101
Issue
19
Pages
193901-193901
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2000650215
Cited by
93
References
1
Citations by year
2026: 3 · 2025: 3 · 2024: 5 · 2023: 8 · 2022: 3 · 2021: 3 · 2020: 5 · 2019: 3 · 2018: 5 · 2017: 6 · 2016: 6 · 2015: 8 · 2014: 8 · 2013: 7 · 2012: 3
FWCI
3.29
Type
journal article
Language
en
Open access
Locations
  • Physical Review Letters (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • Journal of International Crisis and Risk Communication Research (submittedVersion)
  • ENLIGHTEN (Jurnal Bimbingan dan Konseling Islam) (submittedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • arXiv (Cornell University)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum optics and atomic interactions
  • Physical Sciences › Physics and Astronomy › Statistical and Nonlinear Physics › Nonlinear Photonic Systems
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Photorefractive and Nonlinear Optics
Keywords
nonlinearity, stimulated Raman adiabatic passage, dark states, power transfer, excitation power dependence, coupled waveguides

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review