The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Measurements and Simulations of Ultralow Emittance and Ultrashort Electron Beams in the Linac Coherent Light Source
Abstract
The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser project presently in a commissioning phase at the SLAC National Accelerator Laboratory. We report here on very low-emittance measurements made at low bunch charge, and a few femtosecond bunch length produced by the LCLS bunch compressors. Start-to-end simulations associated with these beam parameters show the possibilities of generating hundreds of GW at 1.5 A x-ray wavelength and nearly a single longitudinally coherent spike at 1.5 nm with 2-fs duration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GENESIS 1.3: a fully 3D time-dependent FEL simulation code
Reiche, S. (1999) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(99)00114-x · Cited by 945
Commissioning the Linac Coherent Light Source injector
Akre, R., Dowell, D., Emma, P., Frisch, J., Gilevich, S., Hays, G., Hering, P., Iverson, R., Limborg-Deprey, C., Loos, H., et al. (2008) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.11.030703 · Cited by 247
Self-citationBane, K. L., Decker, F.-J., Ding, Y., Dowell, D. H., Emma, P., Frisch, J., Huang, Z., Iverson, R., Limborg, C., Loos, H., et al. (2009) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.12.030704 · Cited by 57
Self-citation
Cited by
First lasing and operation of an ångstrom-wavelength free-electron laser
Emma, P., Akre, R., Arthur, J., Bionta, R., Bostedt, C., Bozek, J., Brachmann, A., Bucksbaum, P., Coffee, R., Decker, F.-J., et al. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.176 · Cited by 3,167
Self-citationFemtosecond X-ray protein nanocrystallography
Chapman, H. N., Fromme, P., Barty, A., White, T. A., Kirian, R. A., Aquila, A., Hunter, M. S., Schulz, J., DePonte, D. P., Weierstall, U., et al. (2011) · Nature · doi:10.1038/nature09750 · Cited by 2,086
Single mimivirus particles intercepted and imaged with an X-ray laser
Seibert, M. M., Ekeberg, T., Maia, F. R. N. C., Svenda, M., Andreasson, J., Jönsson, O., Odić, D., Iwan, B., Rocker, A., Westphal, D., et al. (2011) · Nature · doi:10.1038/nature09748 · Cited by 904
Self-citationFemtosecond electronic response of atoms to ultra-intense X-rays
Young, L., Kanter, E. P., Krässig, B., Li, Y., March, A. M., Pratt, S. T., Santra, R., Southworth, S. H., Rohringer, N., DiMauro, L. F., et al. (2010) · Nature · doi:10.1038/nature09177 · Cited by 792
The uniform electron gas at warm dense matter conditions
Dornheim, T., Groth, S., & Bonitz, M. (2018) · Physics Reports · doi:10.1016/j.physrep.2018.04.001 · Cited by 264
Metadata
- Authors
- Ding, Y., Brachmann, A., Decker, F.-J., Dowell, D., Emma, P., Frisch, J., Gilevich, S., Hays, G., Hering, P., Huang, Z., Iverson, R., Loos, H., Miahnahri, A., Nuhn, H.-D., Ratner, D., Turner, J., Welch, J., White, W., & Wu, J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2009-06-24
- Volume
- 102
- Issue
- 25
- Pages
- 254801-254801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2614286053
- Cited by
- 316
- References
- 3
- FWCI
- 29.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements and Simulations of Ultralow Emittance and Ultrashort Electron Beams in the Linac Coherent Light Source. https://app.cochat.ai/papers/10.1103/physrevlett.102.254801
- The paper
- Ding, Y., Brachmann, A., Decker, F.-J., Dowell, D., Emma, P., Frisch, J., Gilevich, S., Hays, G., Hering, P., Huang, Z., Iverson, R., Loos, H., Miahnahri, A., Nuhn, H.-D., Ratner, D., Turner, J., Welch, J., White, W., & Wu, J. (2009). Measurements and Simulations of Ultralow Emittance and Ultrashort Electron Beams in the Linac Coherent Light Source. Physical Review Letters. https://doi.org/10.1103/physrevlett.102.254801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.