The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Single-Spin Magnetometry with Multipulse Sensing Sequences
Open accessAbstract
We experimentally demonstrate single-spin magnetometry with multipulse sensing sequences. The use of multipulse sequences can greatly increase the sensing time per measurement shot, resulting in enhanced ac magnetic field sensitivity. We theoretically derive and experimentally verify the optimal number of sensing cycles, for which the effects of decoherence and increased sensing time are balanced. We perform these experiments for oscillating magnetic fields with fixed phase as well as for fields with random phase. Finally, by varying the phase and frequency of the ac magnetic field, we measure the full frequency-filtering characteristics of different multipulse schemes and discuss their use in magnetometry applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Keeping a Quantum Bit Alive by Optimized π -Pulse Sequences
Uhrig, G. S. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.100504 · Cited by 716
Cited by
Nitrogen-Vacancy Centers in Diamond: Nanoscale Sensors for Physics and Biology
Schirhagl, R., Chang, K., Loretz, M., & Degen, C. L. (2014) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040513-103659 · Cited by 1,608
Quantum measurement and orientation tracking of fluorescent nanodiamonds inside living cells
McGuinness, L. P., Yan, Y., Stacey, A., Simpson, D. A., Hall, L. T., Maclaurin, D., Prawer, S., Mulvaney, P., Wrachtrup, J., Caruso, F., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.64 · Cited by 666
Dynamic strain-mediated coupling of a single diamond spin to a mechanical resonator
Ovartchaiyapong, P., Lee, K. W., Myers, B. A., & Jayich, A. C. B. (2014) · Nature Communications · doi:10.1038/ncomms5429 · Cited by 397
A single nitrogen-vacancy defect coupled to a nanomechanical oscillator
Arcizet, O., Jacques, V., Siria, A., Poncharal, P., Vincent, P., & Seidelin, S. (2011) · Nature Physics · doi:10.1038/nphys2070 · Cited by 381
Quantum sensing with arbitrary frequency resolution
Boss, J. M., Cujia, K. S., Zopes, J., & Degen, C. L. (2017) · Science · doi:10.1126/science.aam7009 · Cited by 304
Metadata
- Authors
- de Lange, G., Ristè, D., Dobrovitski, V. V., & Hanson, R.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2011-02-24
- Volume
- 106
- Issue
- 8
- Pages
- 080802-080802
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2084615259
- Cited by
- 209
- References
- 2
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-Spin Magnetometry with Multipulse Sensing Sequences. https://app.cochat.ai/papers/10.1103/physrevlett.106.080802
- The paper
- de Lange, G., Ristè, D., Dobrovitski, V. V., & Hanson, R. (2011). Single-Spin Magnetometry with Multipulse Sensing Sequences. Physical Review Letters. https://doi.org/10.1103/physrevlett.106.080802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.