The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Low-Pump-Power, Low-Phase-Noise, and Microwave to Millimeter-Wave Repetition Rate Operation in Microcombs
Open accessAbstract
Microresonator-based frequency combs (microcombs or Kerr combs) can potentially miniaturize the numerous applications of conventional frequency combs. A priority is the realization of broadband (ideally octave spanning) spectra at detectable repetition rates for comb self-referencing. However, access to these rates involves pumping larger mode volumes and hence higher threshold powers. Moreover, threshold power sets both the scale for power per comb tooth and also the optical pump. Along these lines, it is shown that a class of resonators having surface-loss-limited Q factors can operate over a wide range of repetition rates with minimal variation in threshold power. A new, surface-loss-limited resonator illustrates the idea. Comb generation on mode spacings ranging from 2.6 to 220 GHz with overall low threshold power (as low as 1 mW) is demonstrated. A record number of comb lines for a microcomb (around 1900) is also observed with pump power of 200 mW. The ability to engineer a wide range of repetition rates with these devices is also used to investigate a recently observed mechanism in microcombs associated with dispersion of subcomb offset frequencies. We observe high-coherence phase locking in cases where these offset frequencies are small enough so as to be tuned into coincidence. In these cases, a record-low microcomb phase noise is reported at a level comparable to an open-loop, high-performance microwave oscillator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-high-Q toroid microcavity on a chip
Armani, D. K., Kippenberg, T. J., Spillane, S. M., & Vahala, K. J. (2003) · Nature · doi:10.1038/nature01371 · Cited by 2,214
Self-citation
Cited by
Temporal solitons in optical microresonators
Herr, T., Brasch, V., Jost, J. D., Wang, C. Y., Kondratiev, N. M., Gorodetsky, M. L., & Kippenberg, T. J. (2014) · Nature Photonics · doi:10.1038/nphoton.2013.343 · Cited by 2,122
Dissipative Kerr solitons in optical microresonators
Kippenberg, T. J., Gaeta, A. L., Lipson, M., & Gorodetsky, M. L. (2018) · Science · doi:10.1126/science.aan8083 · Cited by 1,831
Micro-combs: A novel generation of optical sources
Pasquazi, A., Peccianti, M., Razzari, L., Moss, D. J., Coen, S., Erkintalo, M., Chembo, Y. K., Hansson, T., Wabnitz, S., Del’Haye, P., et al. (2018) · Physics Reports · doi:10.1016/j.physrep.2017.08.004 · Cited by 1,074
Microresonator soliton dual-comb spectroscopy
Suh, M.-G., Yang, Q.-F., Yang, K. Y., Yi, X., & Vahala, K. J. (2016) · Science · doi:10.1126/science.aah6516 · Cited by 991
Self-citationAn optical-frequency synthesizer using integrated photonics
Spencer, D. T., Drake, T., Briles, T. C., Stone, J., Sinclair, L. C., Fredrick, C., Li, Q., Westly, D., Ilic, B. R., Bluestone, A., et al. (2018) · Nature · doi:10.1038/s41586-018-0065-7 · Cited by 951
Self-citation
Metadata
- Authors
- Li, J., Lee, H., Chen, T., & Vahala, K. J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2012-12-04
- Volume
- 109
- Issue
- 23
- Pages
- 233901-233901
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2079178639
- Cited by
- 197
- References
- 1
- FWCI
- 9.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.