The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Detecting and Polarizing Nuclear Spins with Double Resonance on a Single Electron Spin
Open accessAbstract
We report the detection and polarization of nuclear spins in diamond at room temperature by using a single nitrogen-vacancy (NV) center. We use Hartmann-Hahn double resonance to coherently enhance the signal from a single nuclear spin while decoupling from the noisy spin bath, which otherwise limits the detection sensitivity. As a proof of principle, we (i) observe coherent oscillations between the NV center and a weakly coupled nuclear spin and (ii) demonstrate nuclear-bath cooling, which prolongs the coherence time of the NV sensor by more than a factor of 5. Our results provide a route to nanometer scale magnetic resonance imaging and novel quantum information processing protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Magnetic Resonance
Slichter, C. P. (1990) · Springer Series in Solid-State Sciences · doi:10.1007/978-3-662-09441-9 · Cited by 5,520
Quantum register based on individual electronic and nuclear spin qubits in diamond
Dutt, M. V. G., Childress, L., Jiang, L., Togan, E., Maze, J., Jelezko, F., Zibrov, A. S., Hemmer, P. R., & Lukin, M. D. (2007) · Science · doi:10.1126/science.1139831 · Cited by 1,287
Self-citation
Cited by
Nuclear magnetic resonance detection and spectroscopy of single proteins using quantum logic
Lovchinsky, I., Sushkov, A. O., Urbach, E., de Leon, N. P., Choi, S., De Greve, K., Evans, R., Gertner, R., Bersin, E., Müller, C., et al. (2016) · Science · doi:10.1126/science.aad8022 · Cited by 536
Self-citationUniversal control and error correction in multi-qubit spin registers in diamond
Taminiau, T. H., Cramer, J., van der Sar, T., Dobrovitski, V. V., & Hanson, R. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.2 · Cited by 429
Diamond Quantum Devices in Biology
Wu, Y., Jelezko, F., Plenio, M. B., & Weil, T. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201506556 · Cited by 292
Self-citationQuantum Error Correction for Metrology
Kessler, E. M., Lovchinsky, I., Sushkov, A. O., & Lukin, M. D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.150802 · Cited by 279
Control of open quantum systems: case study of the central spin model
Arenz, C., Gualdi, G., & Burgarth, D. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/6/065023 · Cited by 39
Metadata
- Authors
- London, P., Scheuer, J., Cai, J.-M., Schwarz, I., Retzker, A., Plenio, M. B., Katagiri, M., Teraji, T., Koizumi, S., Isoya, J., Fischer, R., McGuinness, L. P., Naydenov, B., & Jelezko, F.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2013-08-05
- Volume
- 111
- Issue
- 6
- Pages
- 067601-067601
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2042830823
- Cited by
- 220
- References
- 2
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detecting and Polarizing Nuclear Spins with Double Resonance on a Single Electron Spin. https://app.cochat.ai/papers/10.1103/physrevlett.111.067601
- The paper
- London, P., Scheuer, J., Cai, J.-M., Schwarz, I., Retzker, A., Plenio, M. B., Katagiri, M., Teraji, T., Koizumi, S., Isoya, J., Fischer, R., McGuinness, L. P., Naydenov, B., & Jelezko, F. (2013). Detecting and Polarizing Nuclear Spins with Double Resonance on a Single Electron Spin. Physical Review Letters. https://doi.org/10.1103/physrevlett.111.067601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.