Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 487

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Silicon Detector Dark Matter Results from the Final Exposure of CDMS II

Open access
Agnese, R., Ahmed, Z., Anderson, A. J., Arrenberg, S., Balakishiyeva, D., Basu Thakur, R., Bauer, D. A., Billard, J., Borgland, A., Brandt, D., Brink, P. L., Bruch, T., Bunker, R., Cabrera, B., Caldwell, D. O., Cerdeno, D. G., Chagani, H., Cooley, J., Cornell, B., Crewdson, C. H., Cushman, P., Daal, M., Dejongh, F., do Couto e Silva, E., Doughty, T., Esteban, L., Fallows, S., Figueroa-Feliciano, E., Filippini, J., Fox, J., Fritts, M., Godfrey, G. L., Golwala, S. R., Hall, J., Harris, R. H., Hertel, S. A., Hofer, T., Holmgren, D., Hsu, L., Huber, M. E., Jastram, A., Kamaev, O., Kara, B., Kelsey, M. H., Kennedy, A., Kim, P., Kiveni, M., Koch, K., Kos, M., Leman, S. W., Loer, B., Lopez Asamar, E., Mahapatra, R., Mandic, V., Martinez, C., McCarthy, K. A., Mirabolfathi, N., Moffatt, R. A., Moore, D. C., Nadeau, P., Nelson, R. H., Page, K., Partridge, R., Pepin, M., Phipps, A., Prasad, K., Pyle, M., Qiu, H., Rau, W., Redl, P., Reisetter, A., Ricci, Y., Saab, T., Sadoulet, B., Sander, J., Schneck, K., Schnee, R. W., Scorza, S., Serfass, B., Shank, B., Speller, D., Sundqvist, K. M., Villano, A. N., Welliver, B., Wright, D. H., Yellin, S., Yen, J. J., Yoo, J., Young, B. A., Zhang, J.·2013·Physical Review Letters

Abstract

We report results of a search for weakly interacting massive particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg day of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of ${0.41}_{\ensuremath{-}0.08}^{+0.20}(\mathrm{stat}{)}_{\ensuremath{-}0.24}^{+0.28}(\mathrm{syst})$. Other known backgrounds from neutrons and $^{206}\mathrm{Pb}$ are limited to $<0.13$ and $<0.08$ events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg day for a recoil energy range of 7--100 keV for a WIMP of mass $10\text{ }\text{ }\mathrm{GeV}/{c}^{2}$. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative $\mathrm{\text{WIMP}}+\mathrm{\text{background}}$ hypothesis. The highest likelihood occurs for a WIMP mass of $8.6\text{ }\text{ }\mathrm{GeV}/{c}^{2}$ and WIMP-nucleon cross section of $1.9\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}41}\text{ }\text{ }{\mathrm{cm}}^{2}$.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.111.251301

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 487

Metadata

Authors
Agnese, R., Ahmed, Z., Anderson, A. J., Arrenberg, S., Balakishiyeva, D., Basu Thakur, R., Bauer, D. A., Billard, J., Borgland, A., Brandt, D., Brink, P. L., Bruch, T., Bunker, R., Cabrera, B., Caldwell, D. O., Cerdeno, D. G., Chagani, H., Cooley, J., Cornell, B., Crewdson, C. H., Cushman, P., Daal, M., Dejongh, F., do Couto e Silva, E., Doughty, T., Esteban, L., Fallows, S., Figueroa-Feliciano, E., Filippini, J., Fox, J., Fritts, M., Godfrey, G. L., Golwala, S. R., Hall, J., Harris, R. H., Hertel, S. A., Hofer, T., Holmgren, D., Hsu, L., Huber, M. E., Jastram, A., Kamaev, O., Kara, B., Kelsey, M. H., Kennedy, A., Kim, P., Kiveni, M., Koch, K., Kos, M., Leman, S. W., Loer, B., Lopez Asamar, E., Mahapatra, R., Mandic, V., Martinez, C., McCarthy, K. A., Mirabolfathi, N., Moffatt, R. A., Moore, D. C., Nadeau, P., Nelson, R. H., Page, K., Partridge, R., Pepin, M., Phipps, A., Prasad, K., Pyle, M., Qiu, H., Rau, W., Redl, P., Reisetter, A., Ricci, Y., Saab, T., Sadoulet, B., Sander, J., Schneck, K., Schnee, R. W., Scorza, S., Serfass, B., Shank, B., Speller, D., Sundqvist, K. M., Villano, A. N., Welliver, B., Wright, D. H., Yellin, S., Yen, J. J., Yoo, J., Young, B. A., & Zhang, J.
Venue
Physical Review Letters
Published
2013-12-16
Volume
111
Issue
25
Pages
251301-251301
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2098422406
Cited by
487
References
29
FWCI
53.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Silicon Detector Dark Matter Results from the Final Exposure of CDMS II. https://app.cochat.ai/papers/10.1103/physrevlett.111.251301
The paper
Agnese, R., Ahmed, Z., Anderson, A. J., Arrenberg, S., Balakishiyeva, D., Basu Thakur, R., Bauer, D. A., Billard, J., Borgland, A., Brandt, D., Brink, P. L., Bruch, T., Bunker, R., Cabrera, B., Caldwell, D. O., Cerdeno, D. G., Chagani, H., Cooley, J., Cornell, B., . . . Zhang, J. (2013). Silicon Detector Dark Matter Results from the Final Exposure of CDMS II. Physical Review Letters. https://doi.org/10.1103/physrevlett.111.251301

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.