Cited by 90Optical Polarization and EllipsometryQuantum Information and CryptographyOrbital Angular Momentum in Optics

Optimal Frames for Polarization State Reconstruction

Open access
Foreman, Matthew R., Favaro, Alberto, Aiello, Andrea·2015·Physical Review Letters

Abstract

Complete determination of the polarization state of light requires at least four distinct projective measurements of the associated Stokes vector. Stability of state reconstruction, however, hinges on the condition number κ of the corresponding instrument matrix. Optimization of redundant measurement frames with an arbitrary number of analysis states, m, is considered in this Letter in the sense of minimization of κ. The minimum achievable κ is analytically found and shown to be independent of m, except for m=5 where this minimum is unachievable. Distribution of the optimal analysis states over the Poincaré sphere is found to be described by spherical 2 designs, including the Platonic solids as special cases. Higher order polarization properties also play a key role in nonlinear, stochastic, and quantum processes. Optimal measurement schemes for nonlinear measurands of degree t are hence also considered and found to correspond to spherical 2t designs, thereby constituting a generalization of the concept of mutually unbiased bases.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.115.263901

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The equal spacing of vectors around the Bloch sphere gives the device maximum robustness to errors in the tomography procedure, by essentially realizing non-local measurements.

    “The equal spacing of vectors around the Bloch sphere gives the device maximum robustness to errors in the tomography procedure, 29 by essentially realizing non-local measurements.”

    From Scalable on-chip quantum state tomography (2018) · cites this paper as [29]

    The paper links optimal measurement frames on the Poincaré sphere to reduced error amplification in polarization reconstruction (pp. 1–3). It describes the Bloch sphere only as a geometric parallel that may inform two-level quantum tomography (p. 4); it does not say that the device achieves robustness by realizing non-local measurements. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 5

  1. [5]J. N. Damask, Polarization Optics in Telecommunications , Springer Series in Optical Sciences (SpringerVerlag, New York, New York, 2005).
  2. [11]A. S. Alenin, Matrix Structure for Information Driven Polarimeter Design PhD Thesis (University of Arizona, 2015).
  3. [29]V. V. Prasolov, Problems and theorems in linear algebra , vol. 134 of Translations of Mathematical Monographs (American Mathematical Society, Providence, RI, 1994).
  4. [32]A. Klappenecker and M. R¨ otteler, 'Mutually unbiased bases are complex projective 2-designs,' arXiv:quantph/0502031 (2005).
  5. [37]D. Cox, J. Little, and D. O'Shea, Ideals, varieties, and algorithms (Springer-Verlag, Berlin, 2007).

Cited by

Sorted by citations

  • Scalable on-chip quantum state tomography

    Titchener, J. G., Gräfe, M., Heilmann, R., Solntsev, A. S., Szameit, A., & Sukhorukov, A. A. (2018) · npj Quantum Information · doi:10.1038/s41534-018-0063-5 · Cited by 61 · see citing works

    “The equal spacing of vectors around the Bloch sphere gives the device maximum robustness to errors in the tomography procedure, 29 by essentially realizing non-local measurements.”
    Background

Authors
Foreman, M. R., Favaro, A., & Aiello, A.
Affiliations
  • Max Planck Institute for the Science of Light (DE)
  • Imperial College London (GB)
Venue
Physical Review Letters
Published
2015-12-23
Volume
115
Issue
26
Pages
263901-263901
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2214724883
Cited by
90
References
1
Citations by year
2026: 3 · 2025: 9 · 2024: 9 · 2023: 7 · 2022: 9 · 2021: 5 · 2020: 8 · 2019: 16 · 2018: 9 · 2017: 6 · 2016: 9
FWCI
3.98
Type
journal article
Language
en
Open access
Locations
  • Physical Review Letters (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
  • Spiral (Imperial College London) (submittedVersion)
  • arXiv (Cornell University)
Funders
  • Gordon and Betty Moore Foundation
  • Max-Planck-Gesellschaft
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Polarization and Ellipsometry
  • Physical Sciences › Computer Science › Artificial Intelligence › Quantum Information and Cryptography
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Orbital Angular Momentum in Optics
Keywords
Stokes vector, condition number minimization, Poincaré sphere, Platonic solids, mutually unbiased bases, quantum state tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review