The DOI matches its Crossref record.
Differential Gain and Bistability Using a Sodium-Filled Fabry-Perot Interferometer
Abstract
Differential gain and large hysteresis have been seen in the transmission of a Fabry-Perot interferometer containing Na vapor irradiated by light from a cw dye laser. Non-linear dispersion, neglected in earlier work, dominates over nonlinear absorption in Na. The apparatus uses only optical inputs and outputs. Similar apparatus may be useful as an optical amplifier, memory element, clipper, and limiter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pattern formation outside of equilibrium
Cross, M. C., & Hohenberg, P. C. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.851 · Cited by 7,859
Theory of bistability in nonlinear distributed feedback structures
Winful, H. G., Marburger, J. H., & Garmire, E. (1979) · Applied Physics Letters · doi:10.1063/1.91131 · Cited by 494
Quantum optical tunneling: A representation-free theory valid near the state-equation turning points
Drummond, P. D. (1986) · Physical Review A · doi:10.1103/physreva.33.4462 · Cited by 31
Metadata
- Authors
- Gibbs, H. M., McCall, S. L., & Venkatesan, T. N. C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1976-05-10
- Volume
- 36
- Issue
- 19
- Pages
- 1135-1138
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W2080827655
- Cited by
- 899
- References
- 0
- FWCI
- 26.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differential Gain and Bistability Using a Sodium-Filled Fabry-Perot Interferometer. https://app.cochat.ai/papers/10.1103/physrevlett.36.1135
- The paper
- Gibbs, H. M., McCall, S. L., & Venkatesan, T. N. C. (1976). Differential Gain and Bistability Using a Sodium-Filled Fabry-Perot Interferometer. Physical Review Letters. https://doi.org/10.1103/physrevlett.36.1135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.