The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Quantum-Mechanical Radiation-Pressure Fluctuations in an Interferometer
Abstract
The interferometers now being developed to detect gravitational vaves work by measuring small changes in the positions of free masses. There has been a controversy whether quantum-mechanical radiation-pressure fluctuations disturb this measurement. This Letter resolves the controversy: They do.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sources of Gravitational Radiation
McCarthy, P. J. (1980) · Physics Bulletin · doi:10.1088/0031-9112/31/5/025 · Cited by 745
Wideband laser-interferometer graviational-radiation experiment
Forward, R. L. (1978) · Physical Review D · doi:10.1103/physrevd.17.379 · Cited by 188
Quantum-mechanical limitations in macroscopic experiments and modern experimental technique
Braginskii, V. B., & Vorontsov, Y. I. (1974) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0114.197409b.0041 · Cited by 125
Limits to the measurement of displacement in an interferometric gravitational radiation detector
Edelstein, W. A., Hough, J., Pugh, J. R., & Martin, W. H. (1978) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/11/7/030 · Cited by 91
An argon laser interferometer for the detection of gravitational radiation
Billing, H., Maischberger, K., Rüdiger, A., Schilling, R., Schnupp, L., & Winkler, W. (1979) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/12/11/010 · Cited by 72
Photon Bunching and Antibunching
Loudon, R. (1976) · Physics Bulletin · doi:10.1088/0031-9112/27/1/023 · Cited by 51
Cited by
Aspelmeyer, M., Kippenberg, T. J., & Marquardt, F. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.1391 · Cited by 5,501
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Self-citationQuantum-Enhanced Measurements: Beating the Standard Quantum Limit
Giovannetti, V., Lloyd, S., & Maccone, L. (2004) · Science · doi:10.1126/science.1104149 · Cited by 3,038
Optomechanical Entanglement between a Movable Mirror and a Cavity Field
Vitali, D., Gigan, S., Ferreira, A., Böhm, H. R., Tombesi, P., Guerreiro, A., Vedral, V., Zeilinger, A., & Aspelmeyer, M. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.030405 · Cited by 1,234
Enhanced sensitivity of the LIGO gravitational wave detector by using squeezed states of light
Aasi, J., Abadie, J., Abbott, B. P., Abbott, R., Abbott, T. D., Abernathy, M. R., Adams, C., Adams, T., Addesso, P., Adhikari, R. X., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.177 · Cited by 1,204
Metadata
- Authors
- Caves, C. M.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1980-07-14
- Volume
- 45
- Issue
- 2
- Pages
- 75-79
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W2072766443
- Cited by
- 615
- References
- 6
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.