Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record.

Large-Scale Anisotropy in the 2.7-K Radiation with a Balloon-Borne Maser Radiometer at 24.5 GHz

Fixsen, Dale J., Cheng, Edward S., Wilkinson, David T. · 1983 · Physical Review Letters

Abstract

Observations with a high-sensitivity radiometer, covering 80% of the sky, give substantially improved measurements of anisotropy in the 2.7-K radiation. The dipole effect is $({T}_{x}, {T}_{y}, {T}_{z})=(\ensuremath{-}3.07\ifmmode\pm\else\textpm\fi{}0.17, 0.67\ifmmode\pm\else\textpm\fi{}0.09, \ensuremath{-}0.45\ifmmode\pm\else\textpm\fi{}0.09)$ mK; the Earth's orbital motion through the 2.7-K radiation is detected. No statistically significant quadrupole effect is seen, and a magnitude limit of 0.19 mK is established at the 90% confidence level. Covariance analysis for angular separations between 10\ifmmode^\circ\else\textdegree\fi{} and 180\ifmmode^\circ\else\textdegree\fi{} gives $〈\ensuremath{\delta}{T}_{1}\ensuremath{\delta}{T}_{2}〉<0.01$ ${(\mathrm{mK})}^{2}$.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.50.620

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 160

Metadata

Authors
Fixsen, D. J., Cheng, E. S., & Wilkinson, D. T.
Venue
Physical Review Letters
Published
1983-02-21
Volume
50
Issue
8
Pages
620-622
ISSN
0031-9007 (ISSN-L)
OpenAlex
W1987984506
Cited by
160
References
0
FWCI
32.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Large-Scale Anisotropy in the 2.7-K Radiation with a Balloon-Borne Maser Radiometer at 24.5 GHz. https://app.cochat.ai/papers/10.1103/physrevlett.50.620
The paper
Fixsen, D. J., Cheng, E. S., & Wilkinson, D. T. (1983). Large-Scale Anisotropy in the 2.7-K Radiation with a Balloon-Borne Maser Radiometer at 24.5 GHz. Physical Review Letters. https://doi.org/10.1103/physrevlett.50.620

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.