The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Coherent Phonon Generation and Detection by Picosecond Light Pulses
Abstract
Using the picosecond pump and probe technique we have detected oscillations of photoinduced transmission and reflection in thin films of $a$-${\mathrm{As}}_{2}$${\mathrm{Te}}_{3}$ and cis-polyacetylene. These oscillations are due to the generation and propagation of coherent acoustic phonons in the film. We discuss the generation and detection mechanism, and we use this effect to measure the sound velocity in a film of $a$-Si${\mathrm{O}}_{2}$.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The thickness of the metal (Al) film was 88 nm on average, as confirmed with picosecond ultrasonics [31,32].”
From Mean Free Path Effects on the Experimentally Measured Thermal Conductivity of Single-Crystal Silicon Microbridges (2013) · cites this paper as [32]
Citations
Cites
Phonon Scattering in Condensed Matter
Eisenmenger, W., Laßmann, K., & Döttinger, S. (1984) · Springer series in solid-state sciences · doi:10.1007/978-3-642-82163-9 · Cited by 299
Picosecond Photoinduced Dichroism inTrans- (CH)x : Direct Measurement of Soliton Diffusion
Vardeny, Z. V., Strait, J. H., Moses, D. J., Chung, T., & Heeger, A. J. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.1657 · Cited by 224
Self-citationPhotostriction Effect in Germanium
Figielski, T. (1961) · physica status solidi (b) · doi:10.1002/pssb.19610010403 · Cited by 101
Effect of pressure on optical properties of crystalline As2 S3
Besson, J. M., Cernogora, J., & Zallen, R. (1980) · Physical review. B, Condensed matter · doi:10.1103/physrevb.22.3866 · Cited by 65
Effect of pressure on the elastic properties of vitreous As2 S3
Gerlich, D., Litov, E., & Anderson, O. L. (1979) · Physical review. B, Condensed matter · doi:10.1103/physrevb.20.2529 · Cited by 29
Ultrasonic attenuation in molecular crystals
Perrin, B. (1981) · Physical review. B, Condensed matter · doi:10.1103/physrevb.24.6104 · Cited by 7
Research works printed but not linked: 3
- Z. Vardeny, 1982, Prosecond Phenomena III
- J. Cornet, 1976, 4th International Conference on the Physics of Non-Crystalline Solids
- J. M. Besson, 1981, Physica (Utrecht), 105B, 319
Cited by
Sorted by citations
Surface generation and detection of phonons by picosecond light pulses
Thomsen, C., Grahn, H. T., Maris, H. J., & Tauc, J. (1986) · Physical review. B, Condensed matter · doi:10.1103/physrevb.34.4129 · Cited by 1,636
Self-citationInterfacial thermal resistance: Past, present, and future
Chen, J., Xu, X., Zhou, J., & Li, B. (2022) · Reviews of Modern Physics · doi:10.1103/revmodphys.94.025002 · Cited by 759
Jiang, P., Qian, X., & Yang, R. (2018) · Journal of Applied Physics · doi:10.1063/1.5046944 · Cited by 424
Physical mechanisms of coherent acoustic phonons generation by ultrafast laser action
Ruello, P., & Gusev, V. (2014) · Ultrasonics · doi:10.1016/j.ultras.2014.06.004 · Cited by 399
Laser-generated ultrasound: its properties, mechanisms and multifarious applications
Davies, S., Edwards, C., Taylor, G. S., & Palmer, S. B. (1993) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/26/3/001 · Cited by 368
Metadata
- Authors
- Thomsen, C., Strait, J., Vardeny, Z., Maris, H. J., Tauc, J., & Hauser, J. J.
- Affiliations
- Brown University (US)
- AT&T (United States) (US)
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1984-09-03
- Volume
- 53
- Issue
- 10
- Pages
- 989-992
- ISSN
- 0031-9007 (ISSN-L)
- OpenAlex
- W2083424710
- Cited by
- 581
- References
- 6
- Citations by year
- 2026: 20 · 2025: 25 · 2024: 27 · 2023: 31 · 2022: 34 · 2021: 32 · 2020: 25 · 2019: 26 · 2018: 31 · 2017: 32 · 2016: 23 · 2015: 15 · 2014: 37 · 2013: 30 · 2012: 22
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physical Review Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Optical and Acousto-Optic Technologies
- Keywords
- coherent phonons, cis-polyacetylene, thin films, sound velocity measurement, amorphous silica
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›