Direct Observation of Magnetic Relaxation in a Small Permalloy Disk by Time-Resolved Scanning Kerr Microscopy
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Magnetic oscillations were studied in a single, lithographically patterned disk ( $8\ensuremath{\mu}\mathrm{m}\mathrm{diam}\ifmmode\times\else\texttimes\fi{}0.1\ensuremath{\mu}\mathrm{m}\mathrm{thick}$) of permalloy placed in an in-plane biasing magnetic field, excited by subnanosecond pulses of perpendicular field. Local changes of the perpendicular magnetization component were detected by time-resolved scanning magneto-optical Kerr microscopy, allowing direct observation of the nonuniform spatial evolution of the magnetization. It was found that the modal frequency of the oscillations is very close to the ferromagnetic resonance frequency. The Landau-Lifshitz-Gilbert equation with damping constant equal to 0.008 describes broad features of the data, although departures due to the nonuniform response are also evident.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey of magnetooptic effects
Freiser, M. (1968) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1968.1066210 · Cited by 323
Lederman, M., Schultz, S., & Ozaki, M. (1994) · Physical Review Letters · doi:10.1103/physrevlett.73.1986 · Cited by 235
Statistical Techniques for Data Analysis, Second Edition
Taylor, J. K., & Cihon, C. (2007) · Medical Entomology and Zoology · Cited by 195
Statistical Techniques for Data Analysis
Taylor, J. K., & Cihon, C. (2004) · Chapman & Hall/CRC eBooks · doi:10.1201/9780203492390 · Cited by 98
Picosecond time-resolved magnetization dynamics of thin-film heads
Freeman, M. R., & Smyth, J. F. (1996) · Journal of Applied Physics · doi:10.1063/1.361896 · Cited by 82
Self-citation
Cited by
Kruglyak, V. V., Demokritov, S. O., & Grundler, D. (2010) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/43/26/264001 · Cited by 1,486
Resonant and nonresonant control over matter and light by intense terahertz transients
Kampfrath, T., Tanaka, K., & Nelson, K. A. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.184 · Cited by 1,035
Coherent terahertz control of antiferromagnetic spin waves
Kampfrath, T., Sell, A., Klatt, G., Pashkin, A., Mährlein, S., Dekorsy, T., Wolf, M., Fiebig, M., Leitenstorfer, A., & Huber, R. (2011) · Nature Photonics · doi:10.1038/nphoton.2010.259 · Cited by 1,031
Ordered magnetic nanostructures: fabrication and properties
Martı́n, J. I., Nogués, J., Liu, K., Vicent, J. L., & Schuller, I. K. (2003) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(02)00898-3 · Cited by 889
Electrodynamics of correlated electron materials
Basov, D. N., Averitt, R. D., van der Marel, D., Dressel, M., & Haule, K. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.471 · Cited by 797
Metadata
- Authors
- Hiebert, W. K., Stankiewicz, A., & Freeman, M. R.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1997-08-11
- Volume
- 79
- Issue
- 6
- Pages
- 1134-1137
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2013079327
- Cited by
- 353
- References
- 5
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.