The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High Precision Measurements of the Ground State Hyperfine Structure Interval of Muonium and of the Muon Magnetic Moment
Open accessAbstract
High precision measurements of two Zeeman hyperfine transitions in the ground state of muonium in a strong magnetic field have been made at LAMPF using microwave magnetic resonance spectroscopy and a resonance line narrowing technique. These determine the most precise values of the ground state hyperfine structure interval of muonium $\ensuremath{\Delta}\ensuremath{\nu}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}4463302765(53)\mathrm{Hz}$ $(12\mathrm{ppb})$, and of the ratio of magnetic moments ${\ensuremath{\mu}}_{\ensuremath{\mu}}/{\ensuremath{\mu}}_{p}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}3.18334513(39)$ $(120\mathrm{ppb})$, representing a factor of 3 improvement. Values of the mass ratio ${m}_{\ensuremath{\mu}}/{m}_{e}$ and the fine structure constant $\ensuremath{\alpha}$ are derived from these results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bailey, J., Borer, K., Combley, F., Drumm, H., Eck, C., Farley, F. J. M., Field, J. H., Flegel, W., Hattersley, P. M., Krienen, F., et al. (1979) · Nuclear Physics B · doi:10.1016/0550-3213(79)90292-x · Cited by 428
Cited by
Pohl, R., Antognini, A., Nez, F., Amaro, F. D., Biraben, F., Cardoso, J. M. R., Covita, D. S., Dax, A., Dhawan, S., Fernandes, L. M. P., et al. (2010) · Nature · doi:10.1038/nature09250 · Cited by 1,374
Self-citationMeasurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm
Abi, B., Albahri, T., Al-Kilani, S., Allspach, D., Alonzi, L. P., Anastasi, A., Anisenkov, A., Azfar, F., Badgley, K., Baeßler, S., et al. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.141801 · Cited by 1,272
Self-citationJegerlehner, F., & Nyffeler, A. (2009) · Physics Reports · doi:10.1016/j.physrep.2009.04.003 · Cited by 1,103
CODATA recommended values of the fundamental physical constants: 2006
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.633 · Cited by 952
CODATA recommended values of the fundamental physical constants: 2018
Tiesinga, E., Mohr, P. J., Newell, D. B., & Taylor, B. N. (2021) · Reviews of Modern Physics · doi:10.1103/revmodphys.93.025010 · Cited by 908
Metadata
- Authors
- Liu, W., Boshier, M. G., Dhawan, S., van Dyck, O., Egan, P., Fei, X., Grosse Perdekamp, M., Hughes, V. W., Janousch, M., Jungmann, K., Kawall, D., Mariam, F. G., Pillai, C., Prigl, R., zu Putlitz, G., Reinhard, I., Schwarz, W., Thompson, P. A., & Woodle, K. A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1999-01-25
- Volume
- 82
- Issue
- 4
- Pages
- 711-714
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2120729337
- Cited by
- 292
- References
- 1
- FWCI
- 7.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Precision Measurements of the Ground State Hyperfine Structure Interval of Muonium and of the Muon Magnetic Moment. https://app.cochat.ai/papers/10.1103/physrevlett.82.711
- The paper
- Liu, W., Boshier, M. G., Dhawan, S., van Dyck, O., Egan, P., Fei, X., Grosse Perdekamp, M., Hughes, V. W., Janousch, M., Jungmann, K., Kawall, D., Mariam, F. G., Pillai, C., Prigl, R., zu Putlitz, G., Reinhard, I., Schwarz, W., Thompson, P. A., & Woodle, K. A. (1999). High Precision Measurements of the Ground State Hyperfine Structure Interval of Muonium and of the Muon Magnetic Moment. Physical Review Letters. https://doi.org/10.1103/physrevlett.82.711
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.