Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 292

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High Precision Measurements of the Ground State Hyperfine Structure Interval of Muonium and of the Muon Magnetic Moment

Open access
Liu, W., Boshier, M. G., Dhawan, S., van Dyck, O., Egan, P., Fei, X., Grosse Perdekamp, M., Hughes, V. W., Janousch, M., Jungmann, K., Kawall, D., Mariam, F. G., Pillai, C., Prigl, R., zu Putlitz, G., Reinhard, I., Schwarz, W., Thompson, P. A., Woodle, K. A.·1999·Physical Review Letters

Abstract

High precision measurements of two Zeeman hyperfine transitions in the ground state of muonium in a strong magnetic field have been made at LAMPF using microwave magnetic resonance spectroscopy and a resonance line narrowing technique. These determine the most precise values of the ground state hyperfine structure interval of muonium $\ensuremath{\Delta}\ensuremath{\nu}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}4463302765(53)\mathrm{Hz}$ $(12\mathrm{ppb})$, and of the ratio of magnetic moments ${\ensuremath{\mu}}_{\ensuremath{\mu}}/{\ensuremath{\mu}}_{p}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}3.18334513(39)$ $(120\mathrm{ppb})$, representing a factor of 3 improvement. Values of the mass ratio ${m}_{\ensuremath{\mu}}/{m}_{e}$ and the fine structure constant $\ensuremath{\alpha}$ are derived from these results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.82.711

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 292

Metadata

Authors
Liu, W., Boshier, M. G., Dhawan, S., van Dyck, O., Egan, P., Fei, X., Grosse Perdekamp, M., Hughes, V. W., Janousch, M., Jungmann, K., Kawall, D., Mariam, F. G., Pillai, C., Prigl, R., zu Putlitz, G., Reinhard, I., Schwarz, W., Thompson, P. A., & Woodle, K. A.
Venue
Physical Review Letters
Published
1999-01-25
Volume
82
Issue
4
Pages
711-714
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2120729337
Cited by
292
References
1
FWCI
7.63
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Precision Measurements of the Ground State Hyperfine Structure Interval of Muonium and of the Muon Magnetic Moment. https://app.cochat.ai/papers/10.1103/physrevlett.82.711
The paper
Liu, W., Boshier, M. G., Dhawan, S., van Dyck, O., Egan, P., Fei, X., Grosse Perdekamp, M., Hughes, V. W., Janousch, M., Jungmann, K., Kawall, D., Mariam, F. G., Pillai, C., Prigl, R., zu Putlitz, G., Reinhard, I., Schwarz, W., Thompson, P. A., & Woodle, K. A. (1999). High Precision Measurements of the Ground State Hyperfine Structure Interval of Muonium and of the Muon Magnetic Moment. Physical Review Letters. https://doi.org/10.1103/physrevlett.82.711

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.