The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Penning Trap Measurements of the Masses ofC133s,R87,85b, andN23awith Uncertainties≤0.2ppb
Abstract
We report new values from Penning trap single ion mass spectrometry for the atomic masses of ${}^{133}\mathrm{Cs}$, ${}^{87}\mathrm{Rb}$, ${}^{85}\mathrm{Rb}$, and ${}^{23}\mathrm{Na}$ with uncertainties $\ensuremath{\le}0.2\mathrm{ppb}$, a factor of 100 improvement over the accuracy of previously measured values. We have found $M{(}^{133}\mathrm{Cs})\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}132.905451931(27)u$, $M{(}^{87}\mathrm{Rb})\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}86.909180520(15)u$, $M{(}^{85}\mathrm{Rb})\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}84.911789732(14)u$, and $M{(}^{23}\mathrm{Na})\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}22.9897692807(28)u$. These values are important for new ppb-level determinations of the molar Planck constant ${N}_{A}h$ and the fine-structure constant \ensuremath{\alpha}. With the measurement of ${}^{133}\mathrm{Cs}$ we have increased the mass range for sub-ppb measurements by a factor of 3. From $M{(}^{133}\mathrm{Cs})$ and other values we derive ${\ensuremath{\alpha}}^{\ensuremath{-}1}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}137.0359922(40)$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Mode coupling in a Penning trap:π pulses and a classical avoided crossing
Cornell, E. A., Weisskoff, R. M., Boyce, K. R., & Pritchard, D. E. (1990) · Physical Review A · doi:10.1103/physreva.41.312 · Cited by 181
Self-citation
Cited by
CODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Optics and interferometry with atoms and molecules
Cronin, A. D., Schmiedmayer, J., & Pritchard, D. E. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1051 · Cited by 1,420
Self-citationThe 1983 atomic mass evaluation
Wapstra, A. H., & Audi, G. (1985) · Nuclear Physics A · doi:10.1016/0375-9474(85)90283-0 · Cited by 1,108
CODATA recommended values of the fundamental physical constants: 1998
Mohr, P. J., & Taylor, B. N. (2000) · Reviews of Modern Physics · doi:10.1103/revmodphys.72.351 · Cited by 768
Recent trends in the determination of nuclear masses
Lunney, D., Pearson, J. M., & Thibault, C. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.1021 · Cited by 759
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685
CODATA recommended values of the fundamental physical constants: 2002
Mohr, P. J., & Taylor, B. N. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.1 · Cited by 654
New Determination of the Fine Structure Constant and Test of the Quantum Electrodynamics
Bouchendira, R., Cladé, P., Guellati-Khélifa, S., Nez, F., & Biraben, F. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.080801 · Cited by 568
Cavity control of a single-electron quantum cyclotron: Measuring the electron magnetic moment
Hanneke, D., Fogwell Hoogerheide, S., & Gabrielse, G. (2011) · Physical Review A · doi:10.1103/physreva.83.052122 · Cited by 356
New Determination of the Fine Structure Constant from the ElectrongValue and QED
Gabrielse, G., Hanneke, D., Kinoshita, T., Nio, M., & Odom, B. (2006) · Physical Review Letters · doi:10.1103/physrevlett.97.030802 · Cited by 325
A Preliminary Measurement of the Fine Structure Constant Based on Atom Interferometry
Wicht, A., Hensley, J. M., Sarajlic, E., & Chu, S. (2002) · Physica Scripta · doi:10.1238/physica.topical.102a00082 · Cited by 260
Base units of the SI, fundamental constants and modern quantum physics
Bordé, C. J. (2005) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2005.1635 · Cited by 124
Doppler-cooled ions in a compact reconfigurable Penning trap
McMahon, B. J., Volin, C., Rellergert, W. G., & Sawyer, B. C. (2020) · Physical Review A · doi:10.1103/physreva.101.013408 · Cited by 14
McMahon, B., & Sawyer, B. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.014005 · Cited by 12
Metadata
- Authors
- Bradley, M. P., Porto, J. V., Rainville, S., Thompson, J. K., & Pritchard, D. E.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 1999-11-29
- Volume
- 83
- Issue
- 22
- Pages
- 4510-4513
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1662664704
- Cited by
- 214
- References
- 3
- FWCI
- 24.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.