The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Does Water Vapor Prevent Upscaling Sonoluminescence?
Open accessAbstract
Experimental results for single-bubble sonoluminescence of air bubbles at very low frequency f = 7.1 kHz are presented: In contrast to the predictions of a recent model [S. Hilgenfeldt and D. Lohse, Phys. Rev. Lett. 82, 1036 (1999)], the bubbles are only as bright (10(4)-10(5) photons per pulse) and the pulses as long (approximately 150 ps) as at f = 20 kHz. We can theoretically account for this effect by incorporating water vapor into the model: During the rapid bubble collapse a large amount of water vapor is trapped inside the bubble, resulting in an increased heat capacity and hence lower temperatures, i.e., hindering upscaling. At this low frequency water vapor also dominates the light emission process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Theory of Gases and Liquids
Hirschfelder, J. O., Curtiss, C. F., & Bird, R. B. (1955) · Physics Today · doi:10.1063/1.3061949 · Cited by 11,418
Molecular Theory of Gases and Liquids.
Rice, O. K. (1955) · Journal of the American Chemical Society · doi:10.1021/ja01612a111 · Cited by 3,861
Cavitation and Bubble Dynamics
Brennen, C. E. (2013) · Cambridge University Press eBooks · doi:10.1017/cbo9781107338760 · Cited by 3,265
Bubble dynamics in a compressible liquid. Part 1. First-order theory
Prosperetti, A., & Lezzi, A. M. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086000460 · Cited by 663
Defining the unknowns of sonoluminescence
Barber, B. P., Hiller, R. A., Löfstedt, R., Putterman, S. J., & Weninger, K. R. (1997) · Physics Reports · doi:10.1016/s0370-1573(96)00050-6 · Cited by 541
Principles of General Thermodynamics
Hatsopoulos, G. N., Keenan, J. H., & Butler, H. W. (1966) · Journal of Applied Mechanics · doi:10.1115/1.3625109 · Cited by 302
Photooxidation of Organic Chemicals Catalyzed by Nanoscale MoS2
Thurston, T. R., & Wilcoxon, J. P. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp982337h · Cited by 250
A simple explanation of light emission in sonoluminescence
Hilgenfeldt, S., Grossmann, S., & Lohse, D. (1999) · Nature · doi:10.1038/18842 · Cited by 229
Self-citation
Cited by
Physics of bubble oscillations
Lauterborn, W., & Kurz, T. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/10/106501 · Cited by 816
Sonoluminescence, sonochemistry (H2O2 yield) and bubble dynamics: Frequency and power effects
Kanthale, P., Ashokkumar, M., & Grieser, F. (2008) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2007.03.003 · Cited by 315
Sonoprocessing: From Concepts to Large-Scale Reactors
Meroni, D., Djellabi, R., Ashokkumar, M., Bianchi, C. L., & Boffito, D. C. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00438 · Cited by 265
Soliman, W., Nakano, T., Takada, N., & Sasaki, K. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.116202 · Cited by 80
Metadata
- Authors
- Toegel, R., Gompf, B., Pecha, R., & Lohse, D.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2000-10-09
- Volume
- 85
- Issue
- 15
- Pages
- 3165-3168
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2155639968
- Cited by
- 262
- References
- 8
- FWCI
- 7.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does Water Vapor Prevent Upscaling Sonoluminescence? https://app.cochat.ai/papers/10.1103/physrevlett.85.3165
- The paper
- Toegel, R., Gompf, B., Pecha, R., & Lohse, D. (2000). Does Water Vapor Prevent Upscaling Sonoluminescence? Physical Review Letters. https://doi.org/10.1103/physrevlett.85.3165
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.