Tests of Relativity Using a Cryogenic Optical Resonator
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A 190-day comparison of the optical frequencies defined by an optical cavity and a molecular electronic transition is analyzed for the velocity independence of the speed of light (Kennedy-Thorndike test) and the universality of the gravitational redshift. The modulation of the laboratory velocity and the gravitational potential were provided by Earth's orbital motion around the Sun. We find a velocity-dependence coefficient of (1.9+/-2.1)x10(-5), 3 times lower compared to the best previous test. Alternatively, the data confirm the gravitational redshift for an electronic transition at the 4% level. Prospects for significant improvements of the tests are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonstandard optics from quantum space-time
Gambini, R., & Pullin, J. (1999) · Physical Review D · doi:10.1103/physrevd.59.124021 · Cited by 960
Test of Relativistic Gravitation with a Space-Borne Hydrogen Maser
Vessot, R. F. C., Levine, M. W., Mattison, E. M., Blomberg, E. L., Hoffman, T. E., Nystrom, G. U., Farrel, B. F., Decher, R., Eby, P. B., Baugher, C. R., et al. (1980) · Physical Review Letters · doi:10.1103/physrevlett.45.2081 · Cited by 649
A test theory of special relativity: I. Simultaneity and clock synchronization
Mansouri, R., & Sexl, R. U. (1977) · General Relativity and Gravitation · doi:10.1007/bf00762634 · Cited by 440
Effect of Gravity on Gamma Radiation
Pound, R. V., & Snider, J. L. (1965) · Physical Review · doi:10.1103/physrev.140.b788 · Cited by 302
Postulate versus Observation in the Special Theory of Relativity
Robertson, H. P. (1949) · Reviews of Modern Physics · doi:10.1103/revmodphys.21.378 · Cited by 298
Cited by
Modern Tests of Lorentz Invariance
Mattingly, D. (2005) · Living Reviews in Relativity · doi:10.12942/lrr-2005-5 · Cited by 1,061
Signals for Lorentz violation in electrodynamics
Kostelecký, V. A., & Mewes, M. (2002) · Physical Review D · doi:10.1103/physrevd.66.056005 · Cited by 767
Modern Michelson-Morley Experiment using Cryogenic Optical Resonators
Müller, H., Herrmann, S., Braxmaier, C., Schiller, S., & Peters, A. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.020401 · Cited by 301
Self-citationTu, L.-C., Luo, J., & Gillies, G. T. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/1/r02 · Cited by 303
Metadata
- Authors
- Braxmaier, C., Müller, H., Pradl, O., Mlynek, J., Peters, A., & Schiller, S.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2001-12-14
- Volume
- 88
- Issue
- 1
- Pages
- 010401-010401
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2078730284
- Cited by
- 120
- References
- 5
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.