Photoemission and Ionization ofHe+under Simultaneous Irradiation of Fundamental Laser and High-Order Harmonic Pulses
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We theoretically study the response of ${\mathrm{H}\mathrm{e}}^{+}$ exposed simultaneously to an intense Ti:sapphire laser and its 27th or 13th harmonic pulses. High-order harmonic emission from ${\mathrm{H}\mathrm{e}}^{+}$ is enhanced by many orders of magnitude compared with the case of the fundamental pulse alone. Moreover, while an individual 10 fs laser (wavelength ${\ensuremath{\lambda}}_{F}=800\text{ }\text{ }\mathrm{n}\mathrm{m}$) or its 27th harmonic pulse with a peak intensity of $3\ifmmode\times\else\texttimes\fi{}{10}^{14}$ and ${10}^{13}\text{ }{\mathrm{W}\mathrm{/}\mathrm{c}\mathrm{m}}^{2}$, respectively, ionizes no more than $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ of ${\mathrm{H}\mathrm{e}}^{+}$, their combined pulse leads to a surprisingly high ${\mathrm{H}\mathrm{e}}^{2+}$ yield of $17%$.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma perspective on strong field multiphoton ionization
Corkum, P. B. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.1994 · Cited by 7,217
Calculation of photoemission from atoms subject to intense laser fields
Krause, J. L., Schafer, K. J., & Kulander, K. C. (1992) · Physical Review A · doi:10.1103/physreva.45.4998 · Cited by 501
Burnett, K. (1993) · Journal of Modern Optics · doi:10.1080/09500349314551851 · Cited by 454
Extreme-ultraviolet high-order harmonic pulses in the microjoule range
Hergott, J.-F., Kovacev, M., Merdji, H., Hubert, C., Mairesse, Y., Jean, E., Breger, P., Agostini, P., Carré, B., & Salières, P. (2002) · Physical Review A · doi:10.1103/physreva.66.021801 · Cited by 236
Generation of highly coherent submicrojoule soft x rays by high-order harmonics
Takahashi, E., Nabekawa, Y., Otsuka, T., Obara, M., & Midorikawa, K. (2002) · Physical Review A · doi:10.1103/physreva.66.021802 · Cited by 234
Watanabe, S., Kondo, K., Nabekawa, Y., Sagisaka, A., & Kobayashi, Y. (1994) · Physical Review Letters · doi:10.1103/physrevlett.73.2692 · Cited by 230
Generation of 10-µJ coherent extreme-ultraviolet light by use of high-order harmonics
Takahashi, E., Nabekawa, Y., & Midorikawa, K. (2002) · Optics Letters · doi:10.1364/ol.27.001920 · Cited by 226
27-fs extreme ultraviolet pulse generation by high-order harmonics
Kobayashi, Y., Sekikawa, T., Nabekawa, Y., & Watanabe, S. (1998) · Optics Letters · doi:10.1364/ol.23.000064 · Cited by 176
Harmonic generation from a coherent superposition of states
Watson, J. B., Sanpera, A., Chen, X., & Burnett, K. (1996) · Physical Review A · doi:10.1103/physreva.53.r1962 · Cited by 138
Use of helium double ionization for autocorrelation of an xuv pulse
Nakajima, T., & Nikolopoulos, L. A. A. (2002) · Physical Review A · doi:10.1103/physreva.66.041402 · Cited by 44
Cited by
Strelkov, V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.123901 · Cited by 206
Metadata
- Authors
- Ishikawa, K.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2003-07-24
- Volume
- 91
- Issue
- 4
- Pages
- 043002-043002
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2033132217
- Cited by
- 173
- References
- 13
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photoemission and Ionization ofHe+under Simultaneous Irradiation of Fundamental Laser and High-Order Harmonic Pulses. https://app.cochat.ai/papers/10.1103/physrevlett.91.043002
- The paper
- Ishikawa, K. (2003). Photoemission and Ionization ofHe+under Simultaneous Irradiation of Fundamental Laser and High-Order Harmonic Pulses. Physical Review Letters. https://doi.org/10.1103/physrevlett.91.043002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.