The DOI matches its Crossref record.
Charge Transfer from Ammonia Physisorbed on Nanotubes
Abstract
We report the use of nanotube field-effect transistor devices for chemical sensing in a conducting liquid environment. Detection of ammonia occurs through the shift of the gate voltage dependence of the source-drain current. We attribute this shift to charge transfer from adsorbed ammonia molecules, with the amount of charge estimated to be as small as 40 electrons for the smallest shift detected. Using the concentration dependence of the response as an adsorption isotherm, we are able to measure the amount of charge transfer to be 0.04 electron per ammonia molecule.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
Liu, H., Liu, Y., & Zhu, D. (2011) · J. Mater. Chem. · doi:10.1039/c0jm02922j · Cited by 1,629
Carbon Nanomaterials in Biosensors: Should You Use Nanotubes or Graphene?
Yang, W., Ratinac, K. R., Ringer, S. P., Thordarson, P., Gooding, J. J., & Braet, F. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903463 · Cited by 1,431
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Self-citationCarbon Nanotube Field‐Effect‐Transistor‐Based Biosensors
Allen, B. L., Kichambare, P. D., & Star, A. (2007) · Advanced Materials · doi:10.1002/adma.200602043 · Cited by 782
Self-citationBiosensors based on carbon nanotubes
Balasubramanian, K., & Burghard, M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0314-8 · Cited by 727
Gas Sensor Array Based on Metal-Decorated Carbon Nanotubes
Star, A., Joshi, V., Skarupo, S., Thomas, D., & Gabriel, J.-C. P. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp064371z · Cited by 588
Self-citationCarbon nanotube films for transparent and plastic electronics
Gruner, G. (2006) · Journal of Materials Chemistry · doi:10.1039/b603821m · Cited by 567
Carbon nanotube transistors for biosensing applications
Gruner, G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3400-4 · Cited by 408
Nanoelectronic Carbon Dioxide Sensors
Star, A., Han, T. ‐., Joshi, V., Gabriel, J. ‐. P., & Grüner, G. (2004) · Advanced Materials · doi:10.1002/adma.200400322 · Cited by 319
Self-citationCharge Transfer from Adsorbed Proteins
Bradley, K., Briman, M., Star, A., & Grüner, G. (2004) · Nano Letters · doi:10.1021/nl0349855 · Cited by 282
Self-citation
Metadata
- Authors
- Bradley, K., Gabriel, J.-C. P., Briman, M., Star, A., & Grüner, G.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2003-11-17
- Volume
- 91
- Issue
- 21
- Pages
- 218301-218301
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2011022767
- Cited by
- 192
- References
- 0
- FWCI
- 13.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.