The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
High-Resolutionγ-Ray Radiography Produced by a Laser-Plasma Driven Electron Source
Abstract
An electron beam from a laser-plasma accelerator is converted into a gamma-ray source using bremsstrahlung radiation in a dense material. The gamma-ray beam has a pointlike source size because it is generated by a high quality electron beam with a small source size and a low divergence. Using this gamma-ray source, the radiography of complex and dense objects with submillimeter resolution is performed. It is the first evidence of a gamma-ray source size of a few hundreds micrometers produced with laser-driven accelerators. This size is consistent with results from Monte Carlo simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tajima, T., & Dawson, J. M. (1979) · Physical Review Letters · doi:10.1103/physrevlett.43.267 · Cited by 4,705
A laser–plasma accelerator producing monoenergetic electron beams
Faure, J., Glinec, Y., Pukhov, A., Kiselev, S., Gordienko, S., Lefebvre, E., Rousseau, J.-P., Burgy, F., & Malka, V. (2004) · Nature · doi:10.1038/nature02963 · Cited by 2,129
Self-citationHigh-quality electron beams from a laser wakefield accelerator using plasma-channel guiding
Geddes, C. G. R., Toth, C., van Tilborg, J., Esarey, E., Schroeder, C. B., Bruhwiler, D., Nieter, C., Cary, J., & Leemans, W. P. (2004) · Nature · doi:10.1038/nature02900 · Cited by 2,001
Monoenergetic beams of relativistic electrons from intense laser–plasma interactions
Mangles, S. P. D., Murphy, C. D., Najmudin, Z., Thomas, A. G. R., Collier, J. L., Dangor, A. E., Divall, E. J., Foster, P. S., Gallacher, J. G., Hooker, C. J., et al. (2004) · Nature · doi:10.1038/nature02939 · Cited by 1,977
Envelope analysis of intense laser pulse self-modulation in plasmas
Esarey, E., Krall, J., & Sprangle, P. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.2887 · Cited by 211
Cited by
Principles and applications of compact laser–plasma accelerators
Malka, V., Faure, J., Gauduel, Y. A., Lefebvre, E., Rousse, A., & Phuoc, K. T. (2008) · Nature Physics · doi:10.1038/nphys966 · Cited by 507
Self-citation
Metadata
- Authors
- Glinec, Y., Faure, J., Dain, L. L., Darbon, S., Hosokai, T., Santos, J. J., Lefebvre, E., Rousseau, J. P., Burgy, F., Mercier, B., & Malka, V.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2005-01-18
- Volume
- 94
- Issue
- 2
- Pages
- 025003-025003
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2031821597
- Cited by
- 237
- References
- 5
- FWCI
- 5.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Resolutionγ-Ray Radiography Produced by a Laser-Plasma Driven Electron Source. https://app.cochat.ai/papers/10.1103/physrevlett.94.025003
- The paper
- Glinec, Y., Faure, J., Dain, L. L., Darbon, S., Hosokai, T., Santos, J. J., Lefebvre, E., Rousseau, J. P., Burgy, F., Mercier, B., & Malka, V. (2005). High-Resolutionγ-Ray Radiography Produced by a Laser-Plasma Driven Electron Source. Physical Review Letters. https://doi.org/10.1103/physrevlett.94.025003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.