Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 229

The DOI matches its Crossref record.

Fluorescence Fluctuation Spectroscopy in Subdiffraction Focal Volumes

Open access
Kastrup, Lars, Blom, Hans, Eggeling, Christian, Hell, Stefan W.·2005·Physical Review Letters

Abstract

We establish fluorescence fluctuation spectroscopy (FFS) with nanoscale detection volumes generated by stimulated emission depletion. Our method applies fluorescence correlation spectroscopy and fluorescence intensity distribution analysis to extract molecular information about mobilities and fluorescence emission in solution. The combination of correlation analysis with that of photon intensity distributions reveals a fivefold squeezing of the detection volume over current diffraction-limited systems, which is in full agreement with the simultaneously demonstrated 25-fold reduction in (axial) focal transit time. Our method significantly extends the potential of far-field FFS, including for the noninvasive investigation of molecular reactions at higher concentrations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevlett.94.178104

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 229

Metadata

Authors
Kastrup, L., Blom, H., Eggeling, C., & Hell, S. W.
Venue
Physical Review Letters
Published
2005-05-04
Volume
94
Issue
17
Pages
178104-178104
ISSN
  • 0031-9007 (ISSN-L)
  • 1079-7114
OpenAlex
W2022393754
Cited by
229
References
0
FWCI
7.51
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fluorescence Fluctuation Spectroscopy in Subdiffraction Focal Volumes. https://app.cochat.ai/papers/10.1103/physrevlett.94.178104
The paper
Kastrup, L., Blom, H., Eggeling, C., & Hell, S. W. (2005). Fluorescence Fluctuation Spectroscopy in Subdiffraction Focal Volumes. Physical Review Letters. https://doi.org/10.1103/physrevlett.94.178104

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.