The DOI matches its Crossref record.
Sub-Hertz Optical Frequency Comparisons between Two TrappedYb+171Ions
Abstract
We compare the frequencies of the $6s\text{ }^{2}S_{1/2}(F=0)\ensuremath{\rightarrow}5d\text{ }^{2}D_{3/2}(F=2)$ reference transition in $^{171}\mathrm{Yb}^{+}$ for two single ions stored in independent traps. The quadrupole moment of the $5d\text{ }^{2}D_{3/2}$ state is measured to be $9.32(48)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}40}\text{ }\text{ }{\mathrm{C}\text{ }\mathrm{m}}^{2}$ and from the quadratic Stark shift the relevant scalar and tensor polarizabilities are determined to be ${\ensuremath{\alpha}}_{S}({S}_{1/2})\ensuremath{-}{\ensuremath{\alpha}}_{S}({D}_{3/2})=\ensuremath{-}6.9(1.4)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}40}\text{ }\text{ }{\mathrm{J}\text{ }\mathrm{m}}^{2}/{\mathrm{V}}^{2}$ and ${\ensuremath{\alpha}}_{T}({D}_{3/2})=\ensuremath{-}13.6(2.2)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}40}\text{ }\text{ }{\mathrm{J}\text{ }\mathrm{m}}^{2}/{\mathrm{V}}^{2}$, respectively. In the absence of external perturbations we find a mean frequency difference between the two trapped ions of 0.26(42) Hz, corresponding to a relative difference of $3.8(6.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$. This is comparable to the agreement found in the most accurate comparisons between cesium fountain clocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Self-citationSr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Theory and applications of atomic and ionic polarizabilities
Mitroy, J., Safronova, M. S., & Clark, C. W. (2010) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/43/20/202001 · Cited by 489
Metadata
- Authors
- Schneider, T., Peik, E., & Tamm, C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2005-06-16
- Volume
- 94
- Issue
- 23
- Pages
- 230801-230801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2017837727
- Cited by
- 204
- References
- 0
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sub-Hertz Optical Frequency Comparisons between Two TrappedYb+171Ions. https://app.cochat.ai/papers/10.1103/physrevlett.94.230801
- The paper
- Schneider, T., Peik, E., & Tamm, C. (2005). Sub-Hertz Optical Frequency Comparisons between Two TrappedYb+171Ions. Physical Review Letters. https://doi.org/10.1103/physrevlett.94.230801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.