The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Sensitivity Optical Monitoring of a Micromechanical Resonator with a Quantum-Limited Optomechanical Sensor
Open accessAbstract
We experimentally demonstrate the high-sensitivity optical monitoring of a micromechanical resonator and its cooling by active control. Coating a low-loss mirror upon the resonator, we have built an optomechanical sensor based on a very high-finesse cavity (30 000). We have measured the thermal noise of the resonator with a quantum-limited sensitivity at the 10(-19) m/sqrt[Hz] level, and cooled the resonator down to 5 K by a cold-damping technique. Applications of our setup range from quantum optics experiments to the experimental demonstration of the quantum ground state of a macroscopic mechanical resonator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum-mechanical noise in an interferometer
Caves, C. M. (1981) · Physical Review D · doi:10.1103/physrevd.23.1693 · Cited by 3,202
Cited by
Aspelmeyer, M., Kippenberg, T. J., & Marquardt, F. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.1391 · Cited by 5,501
Radiation-pressure cooling and optomechanical instability of a micromirror
Arcizet, O., Cohadon, P.-F., Briant, T., Pinard, M., & Heidmann, A. (2006) · Nature · doi:10.1038/nature05244 · Cited by 938
Self-citationNear-field cavity optomechanics with nanomechanical oscillators
Anetsberger, G., Arcizet, O., Unterreithmeier, Q. P., Rivière, R., Schliesser, A., Weig, E. M., Kotthaus, J. P., & Kippenberg, T. J. (2009) · Nature Physics · doi:10.1038/nphys1425 · Cited by 499
Self-citationSchliesser, A., Arcizet, O., Rivière, R., Anetsberger, G., & Kippenberg, T. J. (2009) · Nature Physics · doi:10.1038/nphys1304 · Cited by 438
Self-citationQuantum optomechanics—throwing a glance [Invited]
Aspelmeyer, M., Gröblacher, S., Hammerer, K., & Kiesel, N. (2010) · Journal of the Optical Society of America B · doi:10.1364/josab.27.00a189 · Cited by 280
Metadata
- Authors
- Arcizet, O., Cohadon, P.-F., Briant, T., Pinard, M., Heidmann, A., Mackowski, J.-M., Michel, C., Pinard, L., Français, O., & Rousseau, L.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2006-09-26
- Volume
- 97
- Issue
- 13
- Pages
- 133601-133601
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2087223926
- Cited by
- 239
- References
- 1
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Sensitivity Optical Monitoring of a Micromechanical Resonator with a Quantum-Limited Optomechanical Sensor. https://app.cochat.ai/papers/10.1103/physrevlett.97.133601
- The paper
- Arcizet, O., Cohadon, P.-F., Briant, T., Pinard, M., Heidmann, A., Mackowski, J.-M., Michel, C., Pinard, L., Français, O., & Rousseau, L. (2006). High-Sensitivity Optical Monitoring of a Micromechanical Resonator with a Quantum-Limited Optomechanical Sensor. Physical Review Letters. https://doi.org/10.1103/physrevlett.97.133601
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.