The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Long-Term Stability of an Area-Reversible Atom-Interferometer Sagnac Gyroscope
Open accessAbstract
We report the first demonstration of a matter-wave interference gyroscope that meets both the short-term noise and long-term stability requirements for high accuracy navigation. This performance level resulted from implementation of a novel technique to precisely reverse the input axis of the gyroscope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic interferometry using stimulated Raman transitions
Kasevich, M., & Chu, S. (1991) · Physical Review Letters · doi:10.1103/physrevlett.67.181 · Cited by 1,377
Self-citationPrecision Rotation Measurements with an Atom Interferometer Gyroscope
Gustavson, T. L., Bouyer, P., & Kasevich, M. A. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.2046 · Cited by 785
Self-citationRotation sensing with a dual atom-interferometer Sagnac gyroscope
Gustavson, T. L., Landragin, A., & Kasevich, M. A. (2000) · Classical and Quantum Gravity · doi:10.1088/0264-9381/17/12/311 · Cited by 470
Self-citationMeasurement of the Earth's Gravity Gradient with an Atom Interferometer-Based Gravity Gradiometer
Snadden, M., McGuirk, J., Bouyer, P., Haritos, K., & Kasevich, M. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.971 · Cited by 441
Self-citationFundamentals Of High Accuracy Inertial Navigation
Chatfield, A. B. (1997) · American Institute of Aeronautics and Astronautics eBooks · doi:10.2514/4.866463 · Cited by 427
Berman, P. R. (1996) · Cited by 394
Lawrence, A. (1998) · Mechanical Engineering Series · doi:10.1007/978-1-4612-1734-3 · Cited by 217
Characterization of Ring Laser Gyro Performance Using the Allan Variance Method
Ng, L. C., & Pines, D. J. (1997) · Journal of Guidance Control and Dynamics · doi:10.2514/2.4026 · Cited by 105
Quantum theory of atomic clocks and gravito-inertial sensors: an update
Antoine, C., & Bord, C. J. (2003) · Journal of Optics B Quantum and Semiclassical Optics · doi:10.1088/1464-4266/5/2/380 · Cited by 84
Cited by
States of an Ensemble of Two-Level Atoms with Reduced Quantum Uncertainty
Schleier-Smith, M. H., Leroux, I. D., & Vuletić, V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.073604 · Cited by 333
Kitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
Continuous Cold-Atom Inertial Sensor with1 nrad/secRotation Stability
Dutta, I., Savoie, D., Fang, B., Venon, B., Garrido Alzar, C. L., Geiger, R., & Landragin, A. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.183003 · Cited by 284
Scalable Spin Squeezing for Quantum-Enhanced Magnetometry with Bose-Einstein Condensates
Muessel, W., Strobel, H., Linnemann, D., Hume, D. B., & Oberthaler, M. K. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.103004 · Cited by 254
Precision bounds for gradient magnetometry with atomic ensembles
Apellaniz, I., Urizar-Lanz, I., Zimborás, Z., Hyllus, P., & Tóth, G. (2018) · Physical Review A · doi:10.1103/physreva.97.053603 · Cited by 45
Metadata
- Authors
- Durfee, D. S., Shaham, Y. K., & Kasevich, M. A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2006-12-15
- Volume
- 97
- Issue
- 24
- Pages
- 240801-240801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2150089340
- Cited by
- 269
- References
- 9
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-Term Stability of an Area-Reversible Atom-Interferometer Sagnac Gyroscope. https://app.cochat.ai/papers/10.1103/physrevlett.97.240801
- The paper
- Durfee, D. S., Shaham, Y. K., & Kasevich, M. A. (2006). Long-Term Stability of an Area-Reversible Atom-Interferometer Sagnac Gyroscope. Physical Review Letters. https://doi.org/10.1103/physrevlett.97.240801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.