The DOI matches its Crossref record.
Mechanical Detection of Carbon Nanotube Resonator Vibrations
Open accessAbstract
Bending-mode vibrations of carbon nanotube resonators were mechanically detected in air at atmospheric pressure by means of a novel scanning force microscopy method. The fundamental and higher order bending eigenmodes were imaged at up to 3.1 GHz with subnanometer resolution in vibration amplitude. The resonance frequency and the eigenmode shape of multiwall nanotubes are consistent with the elastic beam theory for a doubly clamped beam. For single-wall nanotubes, however, resonance frequencies are significantly shifted, which is attributed to fabrication generating, for example, slack. The effect of slack is studied by pulling down the tube with the tip, which drastically reduces the resonance frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dissipation in nanoelectromechanical systems
Imboden, M., & Mohanty, P. (2014) · Physics Reports · doi:10.1016/j.physrep.2013.09.003 · Cited by 273
Fortini, R., Meyer-Plath, A., Kehren, D., Gernert, U., Jácome, L. A., & Sturm, H. (2020) · Fibers · doi:10.3390/fib8050031 · Cited by 18
Metadata
- Authors
- Garcia-Sanchez, D., San Paulo, A., Esplandiu, M. J., Perez-Murano, F., Forró, L., Aguasca, A., & Bachtold, A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2007-08-20
- Volume
- 99
- Issue
- 8
- Pages
- 085501-085501
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2053628309
- Cited by
- 216
- References
- 0
- FWCI
- 11.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical Detection of Carbon Nanotube Resonator Vibrations. https://app.cochat.ai/papers/10.1103/physrevlett.99.085501
- The paper
- Garcia-Sanchez, D., San Paulo, A., Esplandiu, M. J., Perez-Murano, F., Forró, L., Aguasca, A., & Bachtold, A. (2007). Mechanical Detection of Carbon Nanotube Resonator Vibrations. Physical Review Letters. https://doi.org/10.1103/physrevlett.99.085501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.