The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Influence of Substrate Conductivity on Circulation Reversal in Evaporating Drops
Abstract
Nonuniform evaporation from sessile droplets induces radial convection within the drop, which produces the well-known "coffee-ring" effect. The evaporation also induces a gradient in temperature and consequently a gradient in surface tension, generating a Marangoni flow. Here we investigate theoretically and experimentally the thermal Marangoni flow and establish criteria to gauge its influence. An asymptotic analysis indicates that the direction of the flow depends on the relative thermal conductivities of the substrate and liquid, k_{R} identical withk_{S}/k_{L}, reversing direction at a critical contact angle over the range 1.45<k_{R}<2. We corroborate the theory experimentally and demonstrate that the Marangoni flow can significantly influence the resulting patterns of particle deposition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Capillary flow as the cause of ring stains from dried liquid drops
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (1997) · Nature · doi:10.1038/39827 · Cited by 6,435
Contact line deposits in an evaporating drop
Deegan, R. D., Bakajin, O., Dupont, T. F., Huber, G., Nagel, S. R., & Witten, T. A. (2000) · Physical Review E · doi:10.1103/physreve.62.756 · Cited by 2,300
Single-Crystal Colloidal Multilayers of Controlled Thickness
Jiang, P., Bertone, J. F., Hwang, K. S., & Colvin, V. L. (1999) · Chemistry of Materials · doi:10.1021/cm990080+ · Cited by 2,023
Inkjet Printing for Materials and Devices
Calvert, P. (2001) · Chemistry of Materials · doi:10.1021/cm0101632 · Cited by 1,822
Marangoni Effect Reverses Coffee-Ring Depositions
Hu, H., & Larson, R. G. (2006) · The Journal of Physical Chemistry B · doi:10.1021/jp0609232 · Cited by 1,645
Evaporation of a Sessile Droplet on a Substrate
Hu, H., & Larson, R. G. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp0118322 · Cited by 1,516
Pattern formation in drying drops
Deegan, R. D. (2000) · Physical Review E · doi:10.1103/physreve.61.475 · Cited by 1,297
Analysis of the Effects of Marangoni Stresses on the Microflow in an Evaporating Sessile Droplet
Hu, H., & Larson, R. G. (2005) · Langmuir · doi:10.1021/la0475270 · Cited by 923
Drying-Mediated Self-Assembly of Nanoparticles
Rabani, E., Reichman, D. R., Geissler, P. L., & Brus, L. E. (2003) · Nature · doi:10.1038/nature02087 · Cited by 913
Bacterial swimming and oxygen transport near contact lines
Tuval, I., Cisneros, L., Dombrowski, C., Wolgemuth, C. W., Kessler, J. O., & Goldstein, R. E. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406724102 · Cited by 800
Cited by
A review on suppression and utilization of the coffee-ring effect
Mampallil, D., & Eral, H. B. (2018) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2017.12.008 · Cited by 677
Evaporation of macroscopic sessile droplets
Cazabat, A.-M., & Guéna, G. (2010) · Soft Matter · doi:10.1039/b924477h · Cited by 342
Limbeck, A., Galler, P., Bonta, M., Bauer, G., Nischkauer, W., & Vanhaecke, F. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8858-0 · Cited by 312
Metadata
- Authors
- Ristenpart, W. D., Kim, P. G., Domingues, C., Wan, J., & Stone, H. A.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2007-12-03
- Volume
- 99
- Issue
- 23
- Pages
- 234502-234502
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2036624129
- Cited by
- 598
- References
- 13
- FWCI
- 18.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Substrate Conductivity on Circulation Reversal in Evaporating Drops. https://app.cochat.ai/papers/10.1103/physrevlett.99.234502
- The paper
- Ristenpart, W. D., Kim, P. G., Domingues, C., Wan, J., & Stone, H. A. (2007). Influence of Substrate Conductivity on Circulation Reversal in Evaporating Drops. Physical Review Letters. https://doi.org/10.1103/physrevlett.99.234502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.