Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record.

Numerical studies on the electro-optic detection of femtosecond electron bunches

Open access
Casalbuoni, S., Schlarb, H., Schmidt, B., Schmüser, P., Steffen, B., Winter, A. · 2008 · Physical Review Special Topics - Accelerators and Beams

Abstract

The electro-optic (EO) effect is a powerful diagnostic tool for determining the time profile of ultrashort relativistic electron bunches. When a relativistic bunch passes within a few mm of an electro-optic crystal, its transient electric field is equivalent to a half-cycle THz pulse passing through the crystal. The induced birefringence can be detected with polarized femtosecond laser pulses. A simulation code has been written in order to understand the faithfulness and the limitations of electron bunch shape reconstruction by EO sampling. The THz pulse and the laser pulse are propagated as wave packets through the EO crystal. Alternatively, the response function method is applied. Using experimental data on the material properties of zinc telluride (ZnTe) and gallium phosphide (GaP), the effects of velocity mismatch, pulse shape distortion, and signal broadening are explicitly taken into account. The simulations show that the most severe limitation on the time resolution is given by the transverse-optical (TO) lattice oscillation in the EO crystal. The lowest TO frequency is 5.3 THz in ZnTe and 11 THz in GaP. Only the Fourier components below the TO resonance are usable for the bunch shape reconstruction. This implies that the shortest rms bunch length which can be resolved with moderate distortion amounts to $\ensuremath{\sigma}\ensuremath{\approx}90\text{ }\text{ }\mathrm{fs}$ in ZnTe and $\ensuremath{\sigma}\ensuremath{\approx}50\text{ }\text{ }\mathrm{fs}$ in GaP. The influence of the crystal thickness on the amplitude and width of the EO signal is studied. The optimum thickness is in the range from 100 to $300\text{ }\text{ }\ensuremath{\mu}\mathrm{m}$ for ZnTe and from 50 to $100\text{ }\text{ }\ensuremath{\mu}\mathrm{m}$ for GaP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/physrevstab.11.072802

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Casalbuoni, S., Schlarb, H., Schmidt, B., Schmüser, P., Steffen, B., & Winter, A.
Venue
Physical Review Special Topics - Accelerators and Beams
Published
2008-07-09
Volume
11
Issue
7
ISSN
1098-4402 (ISSN-L)
OpenAlex
W2108413932
Cited by
161
References
0
FWCI
3.59
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.