The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
X-Ray Wavelengths
Abstract
Inconsistencies in accepted values (in x units) of x-ray reference lines have recently been demonstrated, although all are supposedly based on "good" calcite crystals. Factors supporting the selection of the W $K{\ensuremath{\alpha}}_{1}$ line as the X-Ray Wavelength Standard are critically discussed. A review is given of the experimental measurements which are used to establish the wavelength of this line on an absolute angstrom basis. Its value is $\ensuremath{\lambda}$ W $K{\ensuremath{\alpha}}_{1}=(0.2090100\ifmmode\pm\else\textpm\fi{}5 \mathrm{ppm})$ \AA{}. This may be used to define a new unit, denoted by \AA{}*, such that the W $K{\ensuremath{\alpha}}_{1}$ wavelength is exactly 0.2090100 \AA{}*; hence 1\AA{}*=1\AA{}\ifmmode\pm\else\textpm\fi{}5 ppm. The wavelengths of the Ag $K{\ensuremath{\alpha}}_{1}$, Mo $K{\ensuremath{\alpha}}_{1}$, Cu $K{\ensuremath{\alpha}}_{1}$, and the Cr $K{\ensuremath{\alpha}}_{2}$ have been established as secondary standards with probable error of approximately one part per million. Sixty-one additional x-ray lines have been used as reference values in a comprehensive review and reevaluation of more than 2700 emission and absorption wavelengths. The recommended wavelength values are listed in \AA{}* units together with probable errors; corresponding energies are given in keV. A second table lists the wavelengths in numerical order, and likewise includes their energies in keV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reevaluation of X-Ray Atomic Energy Levels
BEARDEN, J. A., & BURR, A. F. (1967) · Reviews of Modern Physics · doi:10.1103/revmodphys.39.125 · Cited by 2,041
Self-citationXCIII. The high-frequency spectra of the elements
Moseley, H. G. J. (1913) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786441308635052 · Cited by 529
Our Knowledge of the Fundamental Constants of Physics and Chemistry in 1965
COHEN, E. R., & DuMOND, J. W. M. (1965) · Reviews of Modern Physics · doi:10.1103/revmodphys.37.537 · Cited by 382
Determination of the isotopic ratios of silicon in rocks
Allenby, R. J. (1954) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(54)90060-5 · Cited by 39
Silicon-Crystal Determination of the Absolute Scale of X-Ray Wavelengths
Henins, I., & Bearden, J. (1964) · Physical Review · doi:10.1103/physrev.135.a890 · Cited by 37
Self-citation
Cited by
Relativistic Calculation of Anomalous Scattering Factors for X Rays
Cromer, D. T., & Liberman, D. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1674266 · Cited by 2,973
Reevaluation of X-Ray Atomic Energy Levels
BEARDEN, J. A., & BURR, A. F. (1967) · Reviews of Modern Physics · doi:10.1103/revmodphys.39.125 · Cited by 2,041
Self-citationX-Ray Fluorescence Yields, Auger, and Coster-Kronig Transition Probabilities
BAMBYNEK, W., CRASEMANN, B., FINK, R. W., FREUND, H. U., MARK, H., SWIFT, C. D., PRICE, R. E., & RAO, P. V. (1972) · Reviews of Modern Physics · doi:10.1103/revmodphys.44.716 · Cited by 1,929
Spectral Distribution of Atomic Oscillator Strengths
FANO, U., & COOPER, J. W. (1968) · Reviews of Modern Physics · doi:10.1103/revmodphys.40.441 · Cited by 1,806
Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100
Storm, L., & Israel, H. I. (1970) · Atomic Data and Nuclear Data Tables · doi:10.1016/s0092-640x(70)80017-1 · Cited by 1,539
Metadata
- Authors
- BEARDEN, J. A.
- Venue
- Reviews of Modern Physics
- Publisher
- American Physical Society (APS)
- Published
- 1967-01-01
- Volume
- 39
- Issue
- 1
- Pages
- 78-124
- ISSN
- 0034-6861 (ISSN-L)
- OpenAlex
- W2027377845
- Cited by
- 1,809
- References
- 5
- FWCI
- 83.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.