Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 396

The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.

High-transition-temperature superconducting quantum interference devices

Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., Clarke, John·1999·Reviews of Modern Physics

Abstract

The advent of high-${T}_{c}$ superconductors gave great impetus to the development of thin-film superconducting quantum interference devices (SQUIDs) for operation at temperatures up to the boiling point of liquid nitrogen, 77 K. The spectral density of the white flux noise can be calculated analytically for rf SQUIDs and by computer simulation for dc SQUIDs; however, observed noise spectral densities are typically an order of magnitude higher. Low-frequency $1/f$ noise from thermally activated vortex motion is a much bigger issue in high-${T}_{c}$ SQUIDs at 77 K than in low-${T}_{c}$ SQUIDs because of the low flux-pinning energies in high-${T}_{c}$ superconductors. The magnitude of the noise depends strongly on the quality of the thin films, and much effort has been expended to improve techniques for depositing ${\mathrm{YBa}}_{2}{\mathrm{Cu}}_{3}{\mathrm{O}}_{7\ensuremath{-}x}$ (YBCO) on lattice-matched single-crystal substrates. Substantial effort has also been invested in the development of new types of Josephson junctions, of which grain-boundary junctions are the most widely used in SQUIDs. Appropriate electronic read-out schemes largely eliminate $1/f$ noise from fluctuations in the junction critical current in both rf and dc SQUIDs. Typical levels of white flux noise are a few $\ensuremath{\mu}{\ensuremath{\Phi}}_{0}{\mathrm{Hz}}^{\mathrm{\ensuremath{-}}1/2}$ (${\ensuremath{\Phi}}_{0}$ is the flux quantum). Magnetometers---consisting of a superconducting flux transformer coupled to a SQUID---achieve a white magnetic-field noise as low as 10 fT ${\mathrm{Hz}}^{\mathrm{\ensuremath{-}}1/2}$, increasing to typically 30 fT ${\mathrm{Hz}}^{\mathrm{\ensuremath{-}}1/2}$ at 1 Hz. When these devices are operated in an unshielded environment, it is important to minimize the motion of trapped vortices and induced supercurrents, which can greatly increase the $1/f$ noise. The ambient noise is far greater than the intrinsic noise of the devices, but can be substantially reduced by various gradiometer configurations. There is now considerable effort to apply high-${T}_{c}$ SQUIDs in magnetocardiology, nondestructive evaluation, microscopy, and geophysics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1103/revmodphys.71.631

Cites

71 of 71 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 71 references

Cited by

See all 396

Metadata

Authors
Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., & Clarke, J.
Venue
Reviews of Modern Physics
Published
1999-04-01
Volume
71
Issue
3
Pages
631-686
ISSN
  • 0034-6861 (ISSN-L)
  • 1539-0756
OpenAlex
W2073535388
Cited by
396
References
71
FWCI
25.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-transition-temperature superconducting quantum interference devices. https://app.cochat.ai/papers/10.1103/revmodphys.71.631
The paper
Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., & Clarke, J. (1999). High-transition-temperature superconducting quantum interference devices. Reviews of Modern Physics. https://doi.org/10.1103/revmodphys.71.631

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.