Cited by 41Plant and Biological Electrophysiology StudiesLight effects on plantsIon Transport and Channel Regulation

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

H+ Fluxes in Excised Samanea Motor Tissue: I. Promotion by Light

Open access
Iglesias, Ana, Satter, Ruth L.·1983·Plant Physiology

Abstract

Previous investigators revealed that white light-promoted leaflet opening in Samanea saman (Jacq) Merrill depends upon K(+) uptake by extensor cells and efflux from flexor cells of the pulvinus, while dark-promoted closure depends upon K(+) fluxes in the opposite directions. We now monitored H(+) fluxes during pulvinar movement to test a model proposing coupled H(+)/K(+) fluxes. H(+) fluxes were monitored by measuring changes in the pH of a weakly buffered solution (initial pH = 5.5) bathing excised strips of extensor or flexor tissue. White light at hour 3 of the usual dark period promoted pulvinar opening, H(+) efflux from extensor cells and uptake by flexor cells, while darkness at hours 2 to 4 of the usual light period promoted pulvinar closure, H(+) uptake by extensor cells and efflux from flexor cells. The following conditions altered H(+) fluxes during dark-promoted closure. (a) Light reversed the directions of the fluxes in both extensor and flexor cells. (b) Anoxia increased the rate of H(+) uptake by extensor cells and promoted H(+) uptake (rather than efflux) by flexor cells, consistent with an outwardly directed H(+) pump. KCN showed similar effects initially, but they were transient. (c) Increase in external pH from 5.5 to 6.7 promoted H(+) efflux (rather than uptake) by extensor cells and increased the rate of H(+) efflux from flexor cells, presumably by decreasing the rate of inward diffusion. (d) Change in external K(+) did not alter H(+) fluxes by extensor cells, but removal of external K(+) decreased the rate of H(+) efflux from flexor cells by 70%. These observations support a model for coupled H(+)/K(+) fluxes in pulvinar cells during light-and dark-promoted leaflet movements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1104/pp.72.2.564

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Extensor cells contain an outwardly directed H+ pump activated by white light and inactivated by darkness, while flexor cells contain an outwardly directed H+ pump with the reverse behavior.

    “Extensor cells contain an outwardly directed H⁺ pump that is activated by white light and inactivated by darkness, while flexor cells contain an outwardly directed H⁺ pump with the reverse behavior, i.e. it is activated by darkness and inactivated by white light (10).”

    From Potassium Channels in Motor Cells of Samanea saman (1988) · cites this paper as [10]

    The Abstract (page unavailable) reports outward net H⁺ flux from extensor tissue in white light and from flexor tissue in darkness, with the flux directions reversing under the opposite illumination. But the CELL LOSING TURGOR model (page unavailable) says net flux can reflect either pump activity or H⁺ permeability; the paper does not establish that light and darkness switch the pumps themselves on and off. The Results also limit the extensor light response to particular hours of the dark period. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. SATTER RL 1979 Leaf movements and tendril curling. In W Haupt, ME Feinleib, eds, Encyclopedia of Plant Physiology, New Series VII, Physiology of Move- ments. Springer-Verlag, Berlin, pp 442-484

Cited by

Sorted by citations

Metadata

Authors
Iglesias, A., & Satter, R. L.
Affiliations
University of Connecticut (US)
Venue
Plant Physiology
Published
1983-06-01
Volume
72
Issue
2
Pages
564-569
ISSN
  • 0032-0889 (ISSN-L)
  • 1532-2548
OpenAlex
W1992724564
Cited by
41
References
1
Citations by year
2025: 1 · 2017: 1 · 2015: 1
FWCI
4.54
Type
journal article
Language
en
Open access
Locations
  • PLANT PHYSIOLOGY (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Agricultural and Biological Sciences › Plant Science › Plant and Biological Electrophysiology Studies
  • Life Sciences › Agricultural and Biological Sciences › Plant Science › Light effects on plants
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
Keywords
H-flux, Samanea saman, pulvinus, leaflet movement, potassium uptake, potassium efflux, anoxia, cyanide, external pH, proton pump

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review