The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The RootChip: An Integrated Microfluidic Chip for Plant Science
Open accessAbstract
Studying development and physiology of growing roots is challenging due to limitations regarding cellular and subcellular analysis under controlled environmental conditions. We describe a microfluidic chip platform, called RootChip, that integrates live-cell imaging of growth and metabolism of Arabidopsis thaliana roots with rapid modulation of environmental conditions. The RootChip has separate chambers for individual regulation of the microenvironment of multiple roots from multiple seedlings in parallel. We demonstrate the utility of The RootChip by monitoring time-resolved growth and cytosolic sugar levels at subcellular resolution in plants by a genetically encoded fluorescence sensor for glucose and galactose. The RootChip can be modified for use with roots from other plant species by adapting the chamber geometry and facilitates the systematic analysis of root growth and metabolism from multiple seedlings, paving the way for large-scale phenotyping of root metabolism and signaling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
Core microbiomes for sustainable agroecosystems
Toju, H., Peay, K. G., Yamamichi, M., Narisawa, K., Hiruma, K., Naito, K., Fukuda, S., Ushio, M., Nakaoka, S., Onoda, Y., et al. (2018) · Nature Plants · doi:10.1038/s41477-018-0139-4 · Cited by 1,077
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
PDMS microfluidics: A mini review
Raj M, K., & Chakraborty, S. (2020) · Journal of Applied Polymer Science · doi:10.1002/app.48958 · Cited by 481
Microbiome Engineering: Synthetic Biology of Plant-Associated Microbiomes in Sustainable Agriculture
Ke, J., Wang, B., & Yoshikuni, Y. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.07.008 · Cited by 406
Live imaging of root–bacteria interactions in a microfluidics setup
Massalha, H., Korenblum, E., Malitsky, S., Shapiro, O. H., & Aharoni, A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1618584114 · Cited by 320
Metadata
- Authors
- Grossmann, G., Guo, W.-J., Ehrhardt, D. W., Frommer, W. B., Sit, R. V., Quake, S. R., & Meier, M.
- Venue
- The Plant Cell
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-12-01
- Volume
- 23
- Issue
- 12
- Pages
- 4234-4240
- ISSN
- 1040-4651 (ISSN-L)
- 1532-298X
- OpenAlex
- W2130284764
- Cited by
- 269
- References
- 1
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The RootChip: An Integrated Microfluidic Chip for Plant Science. https://app.cochat.ai/papers/10.1105/tpc.111.092577
- The paper
- Grossmann, G., Guo, W.-J., Ehrhardt, D. W., Frommer, W. B., Sit, R. V., Quake, S. R., & Meier, M. (2011). The RootChip: An Integrated Microfluidic Chip for Plant Science. The Plant Cell. https://doi.org/10.1105/tpc.111.092577
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.