CoChat

Identification of High-Affinity Slow Anion Channel Blockers and Evidence for Stomatal Regulation by Slow Anion Channels in Guard Cells.

Open access
Schroeder, J. I., Schmidt, C., Sheaffer, J. · 1993 · The Plant Cell
Cited by 115

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Slow anion channels in the plasma membrane of guard cells have been suggested to constitute an important control mechanism for long-term ion efflux, which produces stomatal closing. Identification of pharmacological blockers of these slow anion channels is instrumental for understanding plant anion channel function and structure. Patch clamp studies were performed on guard cell protoplasts to identify specific extracellular inhibitors of slow anion channels. Extracellular application of the anion channel blockers NPPB and IAA-94 produced a strong inhibition of slow anion channels in the physiological voltage range with half inhibition constants (K1/2) of 7 and 10 [mu]M, respectively. Single slow anion channels that had a high open probability at depolarized potentials were identified. Anion channels had a main conductance state of 33 [plus or minus] 8 pS and were inhibited by IAA-94. DIDS, which has been shown to be a potent blocker of rapid anion channels in guard cells (K1/2 = 0.2 [mu]M), blocked less than 20% of peak slow anion currents at extracellular or cytosolic concentrations of 100 [mu]M. The pharmacological properties of slow anion channels described here differ from those recently described for rapid anion channels in guard cells, fortifying the finding that two highly distinct types or modes of voltage- and second messenger-dependent anion channel currents coexist in the guard cell plasma membrane. Bioassays using anion channel blockers provide evidence that slow anion channel currents play a substantial role in the regulation of stomatal closing. Interestingly, slow anion channels may also function as a negative regulator during stomatal opening under the experimental conditions applied here. The identification of specific blockers of slow anion channels reported here permits detailed studies of cell biological functions, modulation, and structural components of slow anion channels in guard cells and other higher plant cells.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1105/tpc.5.12.1831

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 115

Metadata

Authors
Schroeder, J. I., Schmidt, C., & Sheaffer, J.
Venue
The Plant Cell
Published
1993-12-01
Volume
5
Issue
12
Pages
1831-1841
ISSN
  • 1040-4651 (ISSN-L)
  • 1532-298X
OpenAlex
W2153691121
Cited by
115
References
1
FWCI
3.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.