The DOI matches its Crossref record.
Powder pattern indexing with the dichotomy method
Abstract
The efficiency of the successive dichotomy method for powder diffraction pattern indexing [Louër & Louër (1972).J. Appl. Cryst.5, 271–275] has been proved over more than 30 years of usage. Features implemented in the new version of the computer program DICVOL 04 include (i) a tolerance to the presence of impurity (or inaccurately measured) diffraction lines, (ii) a refinement of the `zero-point' position, (iii) a reviewing of all input lines from the solution found from, generally, the first 20 lines, (iv) a cell analysis, based on the concept of the reduced cell, to identify equivalent monoclinic and triclinic solutions, and (v) an optional analysis of input powder data to detect the presence of a significant `zero-point' offset. New search strategies have also been introduced,e.g.each crystal system is scanned separately, within the input volume limits, to limit the risk of missing a solution characterized by a metric lattice singularity. The default values in the input file have been extended to 25 Å for the linear parameters and 2500 Å 3 for the cell volume. The search is carried out exhaustively within the input parameter limits and the absolute error on peak position measurements. Many tests with data from the literature and from powder data of pharmaceutical materials, collected with the capillary technique and laboratory monochromatic X-rays, have been performed with a high success rate, covering all crystal symmetries from cubic to triclinic. Some examples reported as `difficult' cases are also discussed. Additionally, a few recommendations for the correct practice of powder pattern indexing are reported.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Li, Y. Q., Delsing, A. C. A., de With, G., & Hintzen, H. T. (2005) · Chemistry of Materials · doi:10.1021/cm050175d · Cited by 589
A 3.6 V lithium-based fluorosulphate insertion positive electrode for lithium-ion batteries
Recham, N., Chotard, J.-N., Dupont, L., Delacourt, C., Walker, W., Armand, M., & Tarascon, J.-M. (2010) · Nature Materials · doi:10.1038/nmat2590 · Cited by 576
Qiu, L.-G., Li, Z.-Q., Wu, Y., Wang, W., Xu, T., & Jiang, X. (2008) · Chemical Communications · doi:10.1039/b804126a · Cited by 516
Li, Y. Q., Hirosaki, N., Xie, R. J., Takeda, T., & Mitomo, M. (2008) · Chemistry of Materials · doi:10.1021/cm801669x · Cited by 431
Observation of superconductivity at 30∼46K in AxFe2Se2(A = Li, Na, Ba, Sr, Ca, Yb and Eu)
Ying, T. P., Chen, X. L., Wang, G., Jin, S. F., Zhou, T. T., Lai, X. F., Zhang, H., & Wang, W. Y. (2012) · Scientific Reports · doi:10.1038/srep00426 · Cited by 324
Metadata
- Authors
- Boultif, A., & Louër, D.
- Venue
- Journal of Applied Crystallography
- Published
- 2004-09-11
- Volume
- 37
- Issue
- 5
- Pages
- 724-731
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2036427959
- Cited by
- 1,459
- References
- 0
- FWCI
- 22.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Powder pattern indexing with the dichotomy method. https://app.cochat.ai/papers/10.1107/s0021889804014876
- The paper
- Boultif, A., & Louër, D. (2004). Powder pattern indexing with the dichotomy method. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889804014876
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.