The DOI matches its Crossref record.
Improvement of data treatment in small-angle neutron scattering
Abstract
Small-angle neutron scattering has been successfully used since the 1970s. As a general rule, methods to extract the useful signal from that received by the detector are well known and give good results. At the Laboratoire Léon Brillouin, for example, these methods have been employed for a long time. However, the data reduction software has been changed for the following reasons. Problems are encountered if the container of the sample gives a spurious signal or if the scattering angle is so large that its cosine cannot be approximated by 1. In the present paper, generalizations of formulas are made in order to account for these difficulties. The decrease of scattered intensity delivered by an incoherent sample that is often observed at large angles is shown to be only due to a geometrical effect. The consequent modifications of the relations used for the normalization of cells of position-sensitive detectors and for the absolute calibration are given. As for the inherent background of the sample, the contribution of density fluctuations is usually neglected. This contribution is formally given as a function of the contrast lengths and of the isothermal compressibility of the sample. This new result allows numerical evaluations of the different terms of the inherent sample background. Practical examples are given. Finally, several methods, developed at the Laboratoire Léon Brillouin, are given to determine the background properly. They are based on systematic measurements of transmissions and background levels of suitably prepared blank samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Characterization and Analysis of Porosity and Pore Structures
Anovitz, L. M., & Cole, D. R. (2015) · Reviews in Mineralogy and Geochemistry · doi:10.2138/rmg.2015.80.04 · Cited by 1,090
Sanson, C., Diou, O., Thévenot, J., Ibarboure, E., Soum, A., Brûlet, A., Miraux, S., Thiaudière, E., Tan, S., Brisson, A., et al. (2011) · ACS Nano · doi:10.1021/nn102762f · Cited by 489
Self-citationSmall-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Di Cola, E., Cantu’, L., Brocca, P., Rondelli, V., Fadda, G. C., Canelli, E., Martelli, P., Clementino, A., Sonvico, F., Bettini, R., et al. (2019) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2019.110439 · Cited by 36
Metadata
- Authors
- Brûlet, A., Lairez, D., Lapp, A., & Cotton, J.-P.
- Venue
- Journal of Applied Crystallography
- Published
- 2007-01-12
- Volume
- 40
- Issue
- 1
- Pages
- 165-177
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2083442770
- Cited by
- 162
- References
- 0
- FWCI
- 8.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improvement of data treatment in small-angle neutron scattering. https://app.cochat.ai/papers/10.1107/s0021889806051442
- The paper
- Brûlet, A., Lairez, D., Lapp, A., & Cotton, J.-P. (2007). Improvement of data treatment in small-angle neutron scattering. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889806051442
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.