CoChat

A small/wide-angle X-ray scattering instrument for structural characterization of air–liquid interfaces, thin films and bulk specimens

Jeng, U-Ser, Su, Chiu Hun, Su, Chun-Jen, Liao, Kuei-Fen, Chuang, Wei-Tsung, Lai, Ying-Huang, Chang, Je-Wei, Chen, Yi-Jiun, Huang, Yu-Shan, Lee, Ming-Tao, Yu, Kuan-Li, Lin, Jhih-Min, Liu, Din-Goa, Chang, Chia-Feng, Liu, Chin-Yen, Chang, Chien-Hung, Liang, Keng S. · 2010 · Journal of Applied Crystallography
Cited by 178

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

At the National Synchrotron Radiation Research Center, a small/wide-angle X-ray scattering (SAXS/WAXS) instrument has been installed at the BL23A beamline with a superconducting wiggler insertion device. This beamline is equipped with double Si(111) crystal and double Mo/B 4 C multilayer monochromators, and an Si-based plane mirror that can selectively deflect the beam downwards for grazing-incidence SAXS (GISAXS) studies of air–liquid or liquid–liquid interfaces. The SAXS/WAXS instrument, situated in an experimental hutch, comprises collimation, sample and post-sample stages. Pinholes and slits have been incorporated into the beam collimation system spanning a distance of ∼5 m. The sample stage can accommodate various sample geometries for air–liquid interfaces, thin films, and solution and solid samples. The post-sample section consists of a 1 m WAXS section with two linear gas detectors, a vacuum bellows (1–4 m), a two-beamstop system and the SAXS detector system, all situated on a motorized optical bench for motion in six degrees of freedom. In particular, the vacuum bellows of a large inner diameter (260 mm) provides continuous changes of the sample-to-detector distance under vacuum. Synchronized SAXS and WAXS measurements are realized via a data-acquisition protocol that can integrate the two linear gas detectors for WAXS and the area detector for SAXS (gas type or Mar165 CCD); the protocol also incorporates sample changing and temperature control for programmable data collection. The performance of the instrument is illustrated via several different measurements, including (1) simultaneous SAXS/WAXS and differential scanning calorimetry for polymer crystallization, (2) structural evolution with a large ordering spacing of ∼250 nm in a supramolecular complex, (3) SAXS for polymer blends under in situ drawing, (4) SAXS and anomalous SAXS for unilamellar lipid vesicles and metalloprotein solutions, (5) anomalous GISAXS for oriented membranes of Br-labeled lipids embedded with peptides, and (6) GISAXS for silicate films formed in situ at the air–water interface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1107/s0021889809043271

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 178

Metadata

Authors
Jeng, U.-S., Su, C. H., Su, C.-J., Liao, K.-F., Chuang, W.-T., Lai, Y.-H., Chang, J.-W., Chen, Y.-J., Huang, Y.-S., Lee, M.-T., Yu, K.-L., Lin, J.-M., Liu, D.-G., Chang, C.-F., Liu, C.-Y., Chang, C.-H., & Liang, K. S.
Venue
Journal of Applied Crystallography
Published
2009-12-01
Volume
43
Issue
1
Pages
110-121
ISSN
0021-8898 (ISSN-L)
OpenAlex
W1964452986
Cited by
178
References
17
FWCI
5.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A small/wide-angle X-ray scattering instrument for structural characterization of air–liquid interfaces, thin films and bulk specimens. https://app.cochat.ai/papers/10.1107/s0021889809043271
The paper
Jeng, U.-S., Su, C. H., Su, C.-J., Liao, K.-F., Chuang, W.-T., Lai, Y.-H., Chang, J.-W., Chen, Y.-J., Huang, Y.-S., Lee, M.-T., Yu, K.-L., Lin, J.-M., Liu, D.-G., Chang, C.-F., Liu, C.-Y., Chang, C.-H., & Liang, K. S. (2010). A small/wide-angle X-ray scattering instrument for structural characterization of air–liquid interfaces, thin films and bulk specimens. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889809043271

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.