The DOI matches its Crossref record.
A low-background-intensity focusing small-angle X-ray scattering undulator beamline
Abstract
The SAXS/WAXS beamline at the Australian Synchrotron is an advanced and flexible undulator X-ray scattering beamline used for small- and wide-angle X-ray scattering analysis on a wide variety of solids, fluids and surfaces across a diverse range of research and development fields. The beamline has numerous features that minimize the intensity of the instrument background, provide automated stable optics, and allow accurate analysis of very weakly scattering samples. The geometric and intensity requirements of a three-slit collimation system are described in detail for conventional metal and single-crystal germanium slits. Straightforward ray tracing and simple linear projections describe the observed direct beam as well as parasitic background scattering geometry of the beamline at its longest camera length, providing a methodology for the design and operation of similar beamlines. As an aid to instrument design, the limit of background intensity determined by the intensity incident on single-crystal germanium guard slit edges and its q dependence was quantified at 11 keV. Details of the beamline's implementation, underlying optical concept and measured performance are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Devkota, L., Kumar, G., Zhang, P., Raghuwanshi, V. S., & Dhital, S. (2025) · Food Hydrocolloids · doi:10.1016/j.foodhyd.2025.111213 · Cited by 25
Sethi, A., Bruell, S., Ryan, T., Yan, F., Tanipour, M. H., Mok, Y.-F., Draper-Joyce, C., Khandokar, Y., Metcalfe, R. D., Griffin, M. D. W., et al. (2021) · Journal of Molecular Biology · doi:10.1016/j.jmb.2021.167217 · Cited by 18
Metadata
- Authors
- Kirby, N. M., Mudie, S. T., Hawley, A. M., Cookson, D. J., Mertens, H. D. T., Cowieson, N., & Samardzic-Boban, V.
- Venue
- Journal of Applied Crystallography
- Published
- 2013-11-15
- Volume
- 46
- Issue
- 6
- Pages
- 1670-1680
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W1980732767
- Cited by
- 530
- References
- 0
- FWCI
- 41.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A low-background-intensity focusing small-angle X-ray scattering undulator beamline. https://app.cochat.ai/papers/10.1107/s002188981302774x
- The paper
- Kirby, N. M., Mudie, S. T., Hawley, A. M., Cookson, D. J., Mertens, H. D. T., Cowieson, N., & Samardzic-Boban, V. (2013). A low-background-intensity focusing small-angle X-ray scattering undulator beamline. Journal of Applied Crystallography. https://doi.org/10.1107/s002188981302774x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.