The DOI matches its Crossref record.
Processing oscillation diffraction data for very large unit cells with an automatic convolution technique and profile fitting
Abstract
A method is described for the processing of X-ray diffraction data collected on an Arndt–Wonacott rotation camera particularly suitable for crystals with very large unit cells. Since often only single exposures can be obtained before the radiation has damaged such crystals, it is essential to select accurately those reflections which have fully penetrated the sphere of reflection. This requires not only a careful refinement of the crystal setting orientation but also a good knowledge of the mosaic spread plus beam divergence. The necessary parameters can be determined by convoluting the theoretically predicted diffraction pattern against the observed film in search of the maximum similarity. Films taken with the crystal misset by as much as 1° can readily be processed with rotational corrections reproducible to better than 0.01°. The many very weak intensities found in data derived from crystals with very large unit cells can be better measured by using a least-squares fit to a previously determined profile rather than by the usual integration process. Systematic variation of the profile across the surface of the film can be readily accommodated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
[20] Processing of X-ray diffraction data collected in oscillation mode
Otwinowski, Z., & Minor, W. (1997) · Methods in Enzymology · doi:10.1016/s0076-6879(97)76066-x · Cited by 33,475
X-ray structure analysis of a membrane protein complex
Deisenhofer, J., Epp, O., Miki, K., Huber, R., & Michel, H. (1984) · Journal of Molecular Biology · doi:10.1016/s0022-2836(84)80011-x · Cited by 1,926
Structure of the influenza virus glycoprotein antigen neuraminidase at 2.9 Å resolution
Varghese, J. N., Laver, W. G., & Colman, P. M. (1983) · Nature · doi:10.1038/303035a0 · Cited by 891
Structural basis of the action of thermolysin and related zinc peptidases
Matthews, B. W. (1988) · Accounts of Chemical Research · doi:10.1021/ar00153a003 · Cited by 687
Processing diffraction data with mosflm
Leslie, A. G. W., & Powell, H. R. (2007) · NATO Science Series II: Mathematics, Physics and Chemistry · doi:10.1007/978-1-4020-6316-9_4 · Cited by 608
Metadata
- Authors
- Rossmann, M. G.
- Venue
- Journal of Applied Crystallography
- Published
- 1979-04-01
- Volume
- 12
- Issue
- 2
- Pages
- 225-238
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W2070340378
- Cited by
- 226
- References
- 0
- FWCI
- 3.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Processing oscillation diffraction data for very large unit cells with an automatic convolution technique and profile fitting. https://app.cochat.ai/papers/10.1107/s0021889879012218
- The paper
- Rossmann, M. G. (1979). Processing oscillation diffraction data for very large unit cells with an automatic convolution technique and profile fitting. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889879012218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.