Processing and post-refinement of oscillation camera data
The DOI matches its Crossref record.
Abstract
When collecting data using oscillation photography, it is necessary to distinguish between those reflections which have passed completely through the Ewald sphere (`full reflections') and those whose penetration is incomplete (`partial reflections'). Such differentiation requires an accurate knowledge of crystal setting parameters. This is particularly necessary if partial reflections are to be used when adjacent films do not originate from the same crystal. In general this is the case where diffracted intensities are weak, as in crystals of oligomeric proteins and viruses. Estimates of setting parameters can be obtained by comparing a partial reflection on one film with a full observation of the same reflection on the same or another film [Schutt, C. E. & Winkler, F. K. (1977). The Rotation Method in Crystallography, edited by U. W. Arndt & A. J. Wonacott, pp. 173–186. Amsterdam: North-Holland]. A measure of the observed degree of partiality, pobs, can thus be made and related to the calculated value, pcalc, derived from the crystal setting parameters. Least-squares minimization of E = Σω(pobs − pcalc)2 leads to the refinement of (1) the orientation of each crystal, (2) the crystal cell dimensions and (3) each crystal's effective mosaic spread. Examples of this technique are provided from the processing of high-resolution southern bean mosaic virus data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
[20] Processing of X-ray diffraction data collected in oscillation mode
Otwinowski, Z., & Minor, W. (1997) · Methods in Enzymology · doi:10.1016/s0076-6879(97)76066-x · Cited by 33,475
iMOSFLM: a new graphical interface for diffraction-image processing with MOSFLM
Battye, T. G. G., Kontogiannis, L., Johnson, O., Powell, H. R., & Leslie, A. G. W. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910048675 · Cited by 2,860
Self-citationFemtosecond X-ray protein nanocrystallography
Chapman, H. N., Fromme, P., Barty, A., White, T. A., Kirian, R. A., Aquila, A., Hunter, M. S., Schulz, J., DePonte, D. P., Weierstall, U., et al. (2011) · Nature · doi:10.1038/nature09750 · Cited by 2,086
The integration of macromolecular diffraction data
Leslie, A. G. W. (2006) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444905039107 · Cited by 1,341
Self-citationDIALS: implementation and evaluation of a new integration package
Winter, G., Waterman, D. G., Parkhurst, J. M., Brewster, A. S., Gildea, R. J., Gerstel, M., Fuentes-Montero, L., Vollmar, M., Michels-Clark, T., Young, I. D., et al. (2018) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798317017235 · Cited by 1,115
Metadata
- Authors
- Rossmann, M. G., Leslie, A. G. W., Abdel-Meguid, S. S., & Tsukihara, T.
- Venue
- Journal of Applied Crystallography
- Published
- 1979-12-01
- Volume
- 12
- Issue
- 6
- Pages
- 570-581
- ISSN
- 0021-8898 (ISSN-L)
- OpenAlex
- W1992326972
- Cited by
- 142
- References
- 0
- FWCI
- 2.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Processing and post-refinement of oscillation camera data. https://app.cochat.ai/papers/10.1107/s0021889879013273
- The paper
- Rossmann, M. G., Leslie, A. G. W., Abdel-Meguid, S. S., & Tsukihara, T. (1979). Processing and post-refinement of oscillation camera data. Journal of Applied Crystallography. https://doi.org/10.1107/s0021889879013273
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.